Sphereplasty with 3D porous titanium microspheres for thoracolumbar vertebral compression fractures: analysis of clinical efficacy and safety profile of a novel technique.

Barbagallo Giuseppe Maria Vincenzo, Cammarata Giacomo, Grasso Erica, Basile Angelo, Maugeri Andrea, Buscema Giovanni, Fiumanò Giuseppa, Agodi Antonella, Servadei Franco, Certo Francesco

СтатьяПеревод в очереди

Аннотация

PURPOSE: Porous Titanium Microspheres (PTM)-based Sphereplasty has been recently proposed as a novel vertebral augmentation technique for thoracolumbar Vertebral Compression Fractures (VCFs), potentially promoting bony fusion and reducing long-term complications. This study aims to evaluate the clinical efficacy and safety of PTM-based Sphereplasty for the treatment of post-traumatic thoracolumbar VCFs and compared the results with data from the literature on standard PMMA-based kyphoplasty.

METHODS

Fifty-two patients (32 females), treated with PTMs Sphereplasty for 57 post-traumatic AO Spine A1 and A3 thoracolumbar VCFs, were prospectively enrolled. Data on demographics, fracture types, surgical details, pain scores (NRS) and disability (ODI) were analyzed. Imaging included x-ray, MRI and CT. Vertebral Body Height (VBH), Wedge Angle (WA) and Kyphosis Angle (KA) were measured.

RESULTS

Median age was 62.7 years and median follow-up was 334.0 days. Median NRS scores decreased from 8.0 to 4.0 (p < 0.001) and ODI improved from 66.35% to 28.45% (p < 0.001). Radiological evaluation demonstrated median KA values of 6.9° preoperatively, 5.5° postoperatively and 7.71° at final follow-up (p = 0.026). WA decreased from 8.4° to 5.0° and 5.1°, respectively (p < 0.001). Anterior and middle VBH improved significantly, from 19.52 to 21.65 mm (p = 0.003) and from 17.49 to 21.20 mm (p < 0.001), whereas there was no clinically relevant change in cranial and caudal VBHs.

CONCLUSION

Sphereplasty is a safe and effective treatment for post-traumatic thoracolumbar VCFs, providing primary stability, pain relief and functional improvement. PTMs may represent a promising alternative to PMMA kyphoplasty, promoting bony fusion and reducing long-term complications.

Для цитирования: Barbagallo Giuseppe Maria Vincenzo, Cammarata Giacomo, Grasso Erica, Basile Angelo, Maugeri Andrea, Buscema Giovanni, Fiumanò Giuseppa, Agodi Antonella, Servadei Franco, Certo Francesco. Sphereplasty with 3D porous titanium microspheres for thoracolumbar vertebral compression fractures: analysis of clinical efficacy and safety profile of a novel technique.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2026. DOI: 10.1007/s00586-026-10251-5.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.