MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0040-1709486

Медицинская библиотека · Veterinary and comparative orthopaedics and traumatology : V.C.O.T · 2020

Treatment Outcomes for Periprosthetic Femoral Fractures in Cementless Press-Fit Total Hip Replacement.

Monotti Isobel C, Preston Christopher A, Kidd Scott W

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to report outcomes in dogs with periprosthetic femoral fractures associated with a press-fit cementless femoral total hip replacement implant.

MATERIALS AND

METHODS

Electronic medical records and digital radiographs were used to identify dogs with periprosthetic femoral fractures associated with press-fit cementless total hip replacement. Data collected included signalment, weight, time of fracture, cause of fracture, presence of intra-operative fissure, fracture type, repair technique, and clinical and radiographic outcomes. Long-term patient outcome was assessed by communication with owners or referring veterinarians.

RESULTS

Twenty-eight dogs with femoral fracture repair associated with cementless press-fit total hip replacement were identified. Eight of the fractures occurred intraoperatively and 20 occurred at a median of 2 days postoperatively. An oblique or spiral configuration was noted in 19 cases and 15 occurred at the distal end of the femoral stem (type B), with thirteen type B1, one type B2 and one type B3 fractures. Fractures were repaired with non-locking (18/28) or locking-plate fixation (10/28). Cerclage wire was applied around the plate and proximal bone segment in 17/28 dogs. Major complications occurred in 7/28 cases (five deep infection, two mechanical failures). Bone healing was noted in 21/23 cases, for which follow-up radiographic interpretation was available. Return to function was complete in 17 cases, acceptable in 8 cases and unacceptable in 3 cases.

CONCLUSIONS

While cementless total hip replacement periprosthetic femoral fractures can be successfully repaired with lateral plate fixation, the risk of infection appears to be high.

Для цитирования: Monotti Isobel C, Preston Christopher A, Kidd Scott W. Treatment Outcomes for Periprosthetic Femoral Fractures in Cementless Press-Fit Total Hip Replacement.. Veterinary and comparative orthopaedics and traumatology : V.C.O.T. 2020. DOI: 10.1055/s-0040-1709486.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.