m+Medelevator.RU
← Поиск публикаций
Analytica chimica acta · 2026

Large Stokes shift red-emissive CDs-based ternary complexes for ratiometric/visual detection of triethylamine.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Liu Guoliang, Wang Shaofei, Yu Zhendi, Li Xinyu, Gu Miao, Feng Da-Qian

Аннотация

BACKGROUND: As triethylamine (TEA) is a critical indicators for evaluating seafood freshness to ensure edible safety and human health, developing a strategy for rapid, sensitive and on-site monitoring TEA possesses an important research significance.

RESULTS: The novel strategy of constructing ratiometric fluorescent platform for TEA detection is proposed based on ternary nanocomposites. Red-emissive carbon dots (R-CDs) with large Stokes shift were firstly synthesized by using citric acid and neutral red as dual carbon sources while UiO-66-NH2 were prepared by 2-aminoterephthalic acid and zirconium tetrachloride via solvothermal approach. After that, R-CDs and riboflavin (RF) self-assembled on the surface of UiO-66-NH2 to form ternary nanocomposites (R-CDs@UiO-66-NH2@RF), displaying dual-response modes: ratiometric and visual detection of TEA. Under single-excitation at 370 nm, ternary nanocomposites exhibit two emission peaks at 426 and 530 nm which ascribes to R-CDs and RF, respectively. Third, UiO-66-NH2 with large surface area brings R-CDs close proximity to RF, resulting in occurrence of FRET from RF to R-CDs. More interestingly, after the introduction of TEA, the emission intensity at 530 nm appears significant decrease due to photo-induced electron transfer while that at 426 nm nearly keeps the constant. Based on these phenomena, a ratiometric approach for detecting TEA has been proposed with the detection limit of 0.28 nM. Furthermore, intelligent visual sensing approach was also fabricated by combining test strips with smartphone-assisted RGB analysis, achieving on-site monitoring of TEA gas and real-time assessment of seafood freshness.

SIGNIFICANCE: Our present ratiometric/intelligent sensing platform offers a convenient and alternative approach for food safety control.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты