MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/prs.0000000000012298

Медицинская библиотека · Plastic and reconstructive surgery · 2025

Correlation between Passive Stretch and Active Contraction Distance and Characteristics of Musculotendinous Units from WALANT Surgery Study.

Zukawa Mineyuki, Osada Ryusuke, Hirokawa Tatsuro, Wada Hikaru, Satomi Masatoshi, Horikawa Kanoko, Kawaguchi Yoshiharu

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Tendon reconstruction is a difficult procedure with unpredictable results, and evaluating and selecting the appropriate muscle tendon is crucial. To improve the results of tendon reconstruction, the authors investigated active muscle contraction during wide-awake local anesthesia no tourniquet (WALANT) surgery, in which the patient can perform active movements.

METHODS

Among 213 WALANT tendon reconstructions, 148 muscle tendons were evaluated for active contraction distance and passive stretch distance of the muscle tendons, time elapsed before reconstruction, and characteristics and changes in muscle active contraction patterns after verbal instructions.

RESULTS

Active contraction and passive stretch distances showed significant positive correlations and flexor muscles displayed larger distances than extensor muscles. Time elapsed before reconstruction did not correlate with either distance. In the flexor digitorum superficialis muscle, active contraction distance was greater in the grip-related ulnar digits, but the late-phase pattern was more frequent. In the extensor indicis proprius muscle, contraction distance on instruction to extend the thumb was smaller than that when instructed to extend the index finger.

CONCLUSION

WALANT surgery is the only procedure in which active contraction distance and characteristics of muscle tendons can be observed intraoperatively, and it appears useful for tendon transfer.

Для цитирования: Zukawa Mineyuki, Osada Ryusuke, Hirokawa Tatsuro, Wada Hikaru, Satomi Masatoshi, Horikawa Kanoko, Kawaguchi Yoshiharu. Correlation between Passive Stretch and Active Contraction Distance and Characteristics of Musculotendinous Units from WALANT Surgery Study.. Plastic and reconstructive surgery. 2025. DOI: 10.1097/prs.0000000000012298.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.