Primary myotubes as an alternative to the calcium induced calcium release test in diagnosing malignant hyperthermia susceptibility.

Otsuki Sachiko, Mukaida Keiko, Miyoshi Hirotsugu, Kido Kenshiro, Sumii Ayako, Ikeda Tsuyoshi, Kato Takahiro, Yasuda Toshimichi, Horikawa Yousuke T, Ichihara Yasuko, Tsutsumi Yasuo M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Malignant hyperthermia (MH) is caused by the dysregulation of calcium (Ca2+) in skeletal muscle cells. In this study, we evaluated the accuracy of a method for diagnosing susceptibility to MH using myotubes as an alternative to Ca2+-induced Ca2+ release rate (CICR) test.

METHODS

In this retrospective study, we retrospectively analyzed Ca2⁺ kinetics data obtained using fura-2/AM from myotubes that had been cultured from remnant muscle fibers of 98 patients who had previously undergone CICR testing for MH susceptibility in Japan. The 50% effective concentrations (EC50) of caffeine and 4-chloro-m-cresol (4-CmC) were calculated from the concentration response curves. The previously calculated cut-off values (caffeine: 3.62 mM, 4-CmC: 197 μM) were used to diagnose susceptibility to MH. The diagnostic accuracy of myotubes was compared with that of the CICR test. Statistical significance was tested using the Mann-Whitney U test.

RESULTS

The CICR test identified 76 patients as CICR-Positive and 22 patients as CICR-Negative. The EC50 for caffeine was 2.9 (2.4-3.3) and 5.0 (4.5-5.5) mM in the CICR-Positive and CICR-Negative groups, respectively (p < 0.0001). The EC50 of 4-CmC was 130 (116-148) and 249 (226-289) μM in the CICR-Positive and CICR-Negative groups, respectively (p < 0.0001). The sensitivity for caffeine for myotubes was 98.7% (95%CI 92.9-99.9). The specificity for caffeine was 100% (95%CI 85.1-100.0). The sensitivity and specificity for 4-CmC were 100% (95%CI 95.2-100.0) and 100% (84.5-100.0), respectively.

CONCLUSIONS

Myotubes responses to caffeine and 4-CmC can be regarded as a viable alternative to the conventional CICR test; however, further validation is needed before this test supersedes the CICR.

Для цитирования: Otsuki Sachiko, Mukaida Keiko, Miyoshi Hirotsugu, Kido Kenshiro, Sumii Ayako, Ikeda Tsuyoshi, Kato Takahiro, Yasuda Toshimichi, Horikawa Yousuke T, Ichihara Yasuko, Tsutsumi Yasuo M. Primary myotubes as an alternative to the calcium induced calcium release test in diagnosing malignant hyperthermia susceptibility.. Journal of anesthesia. 2026. DOI: 10.1007/s00540-026-03822-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.