MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pmrj.12533

Медицинская библиотека · PM & R : the journal of injury, function, and rehabilitation · 2021

Assessing Diagnostic and Severity Grading Accuracy of Ultrasound Measurements for Carpal Tunnel Syndrome Compared to Electrodiagnostics.

Chen Yin-Ting, Miller Olson Emily K, Lee Sung-Hoon, Sainani Kristin, Fredericson Michael

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The combined sensory index (CSI) is the most sensitive electrodiagnostic criteria for carpal tunnel syndrome (CTS), and the CSI and Bland criteria have been shown to predict surgical treatment outcomes. The proposed ultrasound measurements have not been assessed against the CSI for diagnostic accuracy and grading of CTS severity.

OBJECTIVE

To investigate the use of ultrasound evaluations for both diagnosis and assessment of severity grading of CTS in comparison to electrodiagnostic assessment.

DESIGN

All patients underwent an electrodiagnostic evaluation using the CSI and Bland severity grading. Each patient underwent an ultrasound evaluation including cross-sectional area (CSA), the change in CSA from the forearm to the tunnel (∆CSA), and the wrist-forearm ratio (WFR). These measurements were assessed for diagnostic and severity grading accuracy using the CSI as the gold standard.

SETTING

Tertiary academic center.

PARTICIPANTS

All patients referred for electrodiagnostic evaluation for CTS were eligible for the study. Only those with idiopathic CTS were included and those with prior CTS treatment were also excluded. Ninety-five patients were included in the study.

INTERVENTIONS: Not applicable.

MAIN OUTCOME MEASURES: The primary study outcome measure was concordance between CSI diagnosis and severity categories and the ultrasound measurements. Both outcomes were also assessed using Bland criteria.

RESULTS

Optimal cut-points for diagnosis of CTS were found to be CSA ≥12 mm2 , ∆CSA ≥4 mm2 , WFR ≥1.4. Using these cut-points, C-statistics comparing diagnosis of CTS using ultrasound measurements versus using the CSI ranged from 0.893-0.966. When looking at CSI severity grading compared to ∆CSA, however, the C-statistics were 0.640-0.661 with substantial overlap between severity groups.

CONCLUSIONS

Although ultrasound measurements had high diagnostic accuracy for CTS based on the CSI criteria, ultrasound measurements were unable to adequately distinguish between CSI severity groups among patients with CTS.

Для цитирования: Chen Yin-Ting, Miller Olson Emily K, Lee Sung-Hoon, Sainani Kristin, Fredericson Michael. Assessing Diagnostic and Severity Grading Accuracy of Ultrasound Measurements for Carpal Tunnel Syndrome Compared to Electrodiagnostics.. PM & R : the journal of injury, function, and rehabilitation. 2021. DOI: 10.1002/pmrj.12533.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.