BACKGROUND

This study compared sugammadex and neostigmine as agents for routine neuromuscular blockade reversal in video-assisted thoracoscopic surgery (VATS) to determine the optimal choice that achieves a shorter operation time and improved turnover efficiency while enhancing postoperative outcomes and ensuring patient safety during thoracic surgery.

METHODS

This prospective study, conducted from July 2022 to March 2023, compared the effect of sugammadex and neostigmine on operation time and turnover efficiency in VATS, involving 60 participants randomly assigned to either group, with the primary objective of identifying the optimal anesthesia reversal choice for improved outcomes and patient safety during thoracic surgery.

RESULTS

In the study, the sugammadex group showed a significantly shorter total operation room occupancy time (130 ± 7 vs 157 ± 7 minutes; p = 0.009) than the neostigmine group. Patients in the neostigmine group had higher mean pulse rates when leaving the operation room (85 ± 3 vs 73 ± 3 beats/min; p = 0.002) and 120 minutes later in the postanesthesia care unit (76 ± 2 vs 68 ± 2; p = 0.016).

CONCLUSION

This study's findings suggest that sugammadex may enhance total operating room occupancy time, operation turnover efficacy, and respiratory recovery outcomes in VATS, potentially improving patient care and anesthesia management.

Для цитирования: Lin Yu-Tsen, Ting Chien-Kun, Hsu Han-Shui. Sugammadex shortens operation time and improves operation turnover efficacy in video-assisted thoracoscopic surgery.. Journal of the Chinese Medical Association : JCMA. 2024. DOI: 10.1097/jcma.0000000000001080.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.