DOI 10.1080/02713683.2022.2162087

Медицинская библиотека · Current eye research · 2022

Introduction and Clinical Validation of an Updated Biomechanically Corrected Intraocular Pressure bIOP (v2).

Eliasy Ashkan, Lopes Bernardo T, Wang Junjie, Abass Ahmed, Vinciguerra Riccardo, Vinciguerra Paolo, Bao Fang-Jun, Elsheikh Ahmed

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To improve the stability of the Corvis ST biomechanically-corrected intraocular pressure measurements (bIOP) after refractive surgery and its independence of corneal biomechanics.

METHODS

A parametric study was carried out using numerical models simulating the behavior of the eye globe under the effects of IOP and Corvis ST external air pressure and used to develop a new algorithm for bIOP; bIOP(v2). It was tested on 528 healthy participants to evaluate correlations with CCT and age. Its ability to compensate for the geometrical changes was tested in 60 LASIK and 80 SMILE patients with six months follow up. The uncorrected Corvis ST IOP (CVS-IOP) and the two versions of biomechanically corrected IOP; bIOP(v1) and bIOP(v2), were compared.

RESULTS

In the healthy dataset, bIOP(v2) had weak and non-significant correlation with both CCT (R = -0.048, p = .266) and age (R = 0.085, p = .052). For bIOP(v1), the correlation was non-significant with CCT (R = -0.064, p = .139) but significant with age (R = -0.124, p < .05). In both LASIK and SMILE groups, the median change in bIOP(v2) following surgery was below 1 mmHg at follow-up stages and the interquartile range was smaller than both bIOP(v1) and CVS-IOP.

CONCLUSION

The bIOP(v2) algorithm performs better than bIOP(v1) and CVS-IOP in terms of correlation with CCT and age. The bIOP(v2) also demonstrated the smallest variation after LASIK and SMILE refractive surgeries indicating improved ability to compensate for geometrical changes.

Для цитирования: Eliasy Ashkan, Lopes Bernardo T, Wang Junjie, Abass Ahmed, Vinciguerra Riccardo, Vinciguerra Paolo, Bao Fang-Jun, Elsheikh Ahmed. Introduction and Clinical Validation of an Updated Biomechanically Corrected Intraocular Pressure bIOP (v2).. Current eye research. 2022. DOI: 10.1080/02713683.2022.2162087.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.