Lingual thyroid: diagnosis using a hybrid of single photon emission computed tomography and standard computed tomography.

Dolezal J, Vizda J, Horacek J, Spitalnikova S

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To present a rare case of lingual thyroid detected using a hybrid of single photon emission computed tomography and standard computed tomography in a young woman with hypothyroidism.

MATERIALS AND

METHODS

A 29-year-old woman was screened for autoimmune thyroid disorders in early pregnancy, and found to have subclinical hypothyroidism. No thyroid tissue was found in the anterior neck upon ultrasonography, raising suspicions of an ectopic thyroid. The patient was treated with levothyroxine throughout the remainder of her pregnancy, and developed postpartum thyroiditis requiring an increase in levothyroxine dosage. Whole-body scintigraphy and zoomed static head and neck scintigraphy were performed. Abnormal 99mTc-pertechnetate uptake was observed in the oral region, whereas no uptake was found in the usual thyroid location. Hybrid imaging using single photon emission computed tomography and standard computed tomography was performed to improve three-dimensional representation of the area of increased activity.

RESULTS

The latter imaging modality detected ectopic thyroid tissue in the tongue.

CONCLUSION

Whole body 99mTc-pertechnetate scintigraphy and a hybrid of single photon emission computed tomography and standard computed tomography are effective imaging modalities for the investigation of ectopic thyroid tissue. The latter modality is particularly recommended, as it allows more precise spatial visualisation of increased isotope uptake activity in the head and neck.

Для цитирования: Dolezal J, Vizda J, Horacek J, Spitalnikova S. Lingual thyroid: diagnosis using a hybrid of single photon emission computed tomography and standard computed tomography.. The Journal of laryngology and otology. 2013. DOI: 10.1017/s0022215112003246.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.