MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13961

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2020

Ultrasound-guided venipuncture for implantation of cardiac implantable electronic devices: A single-center, retrospective study.

Deluca Giovanni, Massari Vincenzo F M, Musaico Francesco, Rosa Isabella, Modugno Giuseppe, Scardigno Antonio Davide, Valente Leonardo, Leo Pasquale Di, Ceravolo Gianluca, Pittiruti Mauro

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The venous access for the insertion of permanent leads of cardiac implantable electronic devices is often achieved by venous cutdown of the cephalic vein, or by "blind" puncture of the subclavian vein using anatomical landmarks, or by fluoroscopy-assisted methods.

METHODS

We have retrospectively analyzed our clinical experience to verify the feasibility, the safety, and efficacy of the adoption of ultrasound-guided puncture/cannulation of the axillary vein for this purpose.

RESULTS

Nine hundred eighty-seven leads were placed during 548 consecutive procedures, accessing the axillary vein in the infraclavicular area using real-time ultrasound guidance. Venipuncture was successful in 99.8% of cases. The access time was 11 seconds (range 4-580). We recorded three cases of pneumothorax (0.5%), but no hemothorax and no hemo-mediastinum. The incidence of local hematoma was 2.1% (12 cases). No injury to the brachial plexus or to the phrenic nerve was recorded. In a follow-up of 33 months (range 16-39), we observed no cases of "subclavian crush syndrome" (damage of the leads at the level of the thoracic inlet), and the rate of pocket infection/infective endocarditis was 0.7%.

CONCLUSION

In our experience, ultrasound-guided puncture/cannulation of the axillary vein for implantation of permanent leads is feasible, effective, and safe. It might be considered as a first option for this procedure.

Для цитирования: Deluca Giovanni, Massari Vincenzo F M, Musaico Francesco, Rosa Isabella, Modugno Giuseppe, Scardigno Antonio Davide, Valente Leonardo, Leo Pasquale Di, Ceravolo Gianluca, Pittiruti Mauro. Ultrasound-guided venipuncture for implantation of cardiac implantable electronic devices: A single-center, retrospective study.. Pacing and clinical electrophysiology : PACE. 2020. DOI: 10.1111/pace.13961.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.