DOI 10.1016/j.resuscitation.2020.10.004

Медицинская библиотека · Resuscitation · 2020

Comparing the effect of two different interfaces on breathing of preterm infants at birth: A matched-pairs analysis.

Kuypers Kristel L A M, Lamberska Tereza, Martherus Tessa, Dekker Janneke, Böhringer Stefan, Hooper Stuart B, Plavka Richard, Te Pas Arjan B

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Applying a face mask could provoke a trigeminocardiac reflex. We compared the effect of applying bi-nasal prongs with a face mask on breathing and heart rate of preterm infants at birth.

METHODS

In a retrospective matched-pairs study of infants <32 weeks of gestation, the use of bi-nasal prongs for respiratory support at birth was compared to the use of a face mask. Infants who were initially breathing at birth and subsequently received respiratory support were matched for gestational age (±4 days), birth weight (±300 g), general anaesthesia and gender. Breathing, heart rate and other parameters were collected before and after interface application and in the first 5 min thereafter.

RESULTS

In total, 130 infants were included (n = 65 bi-nasal prongs, n = 65 face mask) with a median (IQR) gestational age of 27+2 (25+3-28+4) vs 26+6 (25+3-28+5) weeks. The proportion of infants who stopped breathing after applying the interface was not different between the groups (bi-nasal prongs 43/65 (66%) vs face mask 46/65 (71%), p = 0.70). Positive pressure ventilation was given more often when bi-nasal prongs were used (55/65 (85%) vs 40/65 (62%), p < 0.001). Heart rate (101 (75-145) vs 110 (68-149) bpm, p = 0.496) and oxygen saturation (59% (48-87) vs 56% (35-84), p = 0.178) were similar in the first 5 min after an interface was applied in the infants who stopped breathing.

CONCLUSION

Apnoea and bradycardia occurred often after applying either bi-nasal prongs or a face mask on the face for respiratory support in preterm infants at birth.

Для цитирования: Kuypers Kristel L A M, Lamberska Tereza, Martherus Tessa, Dekker Janneke, Böhringer Stefan, Hooper Stuart B, Plavka Richard, Te Pas Arjan B. Comparing the effect of two different interfaces on breathing of preterm infants at birth: A matched-pairs analysis.. Resuscitation. 2020. DOI: 10.1016/j.resuscitation.2020.10.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.