MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1532-950x.2008.00461.x

Медицинская библиотека · Veterinary surgery : VS · 2008

A tapered-sleeve transcortical pin external skeletal fixation device for use in horses: development, application, and experience.

Nunamaker David M, Nash Ronald A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To report development, configuration, application, and results of a tapered-sleeve transcortical pin external skeletal fixation device (TSP ESFD) for use on fractures of the distal aspect of the equine limb.

STUDY

DESIGN

Optimization analysis of a TSP ESFD was carried out with mechanical testing and review of clinical case outcomes.

ANIMALS: Cadaveric adult third metacarpal bones (MC3) for mechanical testing; horses (n=7) with severely comminuted proximal (6; P1) or second (1) phalanx fractures.

METHODS

Mechanical testing of methods for attachment of TSP to the sidebars were tested as well as optimization of pin diameters. Outcome of clinical cases managed with the TSP ESFD were compared with outcomes of horses treated with previous ESFD.

RESULTS

A TSP ESFD using 7.94 mm diameter pins was used. Survival rate was 71%. One horse with an infected P1 fracture and contralateral laminitis subsequently fractured MC3 through the distal pin hole while wearing the TSP ESFD. One mare with contralateral laminitis was euthanatized. Three horses had open fractures.

CONCLUSIONS

Design improvements incorporated into the TSP ESFD should increase treatment success.

CLINICAL RELEVANCE: External skeletal fixation continues to be a viable treatment alternative for severe injuries of the distal aspect of the equine limb. TSP ESFD should improve on the success of treatment by decreasing complications of bone fracture at the pin interface.

Для цитирования: Nunamaker David M, Nash Ronald A. A tapered-sleeve transcortical pin external skeletal fixation device for use in horses: development, application, and experience.. Veterinary surgery : VS. 2008. DOI: 10.1111/j.1532-950x.2008.00461.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.