DOI 10.1097/md.0000000000007187
The malposition of a central venous catheter through a sheath introducer via the left internal jugular vein: A case report.
Аннотация
RATIONALE: The misplacement of central venous catheter (CVC) can occur more often at the left jugular vein than the right side due to anatomic differences. And many of the previously reported cases are about catheter misplacement resulting from vessel penetration associated with guidewire. This case differs that the catheter itself through the sheath introducer can cause venous injury that may lead to the malposition of CVC particularly through an approach to the left internal jugular vein.
PATIENT CONCERNS, DIAGNOSIS, INTERVENTIONS, AND OUTCOMES: We cannulated a large-bore CVC with a sheath introducer, namely mult-lumen access catheter (MAC) in the left jugular vein of patient under anesthesia using ultrasound and inserted the additional central venous oximetry catheter through the sheath introducer of MAC and confirmed aspiration of blood. However, the postoperative imaging study revealed malposition of the tip of the oximetry catheter in the mediastinum.
MAIN LESSON: The insertion of additional catheter through the sheath introducer needs to be carried out as carefully as the insertion of guidewire and should be confirmed with imaging study after the procedure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.