Measurement of serum antigen concentration by ultrasound-enhanced immunoassay and correlation with clinical outcome in meningococcal disease.

Sobanski M A, Barnes R A, Gray S J, Carr A D, Kaczmarski E B, O'Rourke A, Murphy K, Cafferkey M, Ellis R W, Pidcock K, Hawtin P, Coakley W T

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The distribution of Neisseria meningitidis serogroup B and C polysaccharide antigen in blood and the prognostic significance of antigen concentration was examined by ultrasound-enhanced immunoagglutination of coated microparticles. Specimens (169 sera/plasma from 145 patients with confirmed meningococcal disease) were tested retrospectively. The ultrasonic immunoassay detected serum antigen in 136 samples from 112 patients. Titration of antigen-positive specimens allowed estimation of blood antigen concentration. The modal blood antigen titre was 1/16, corresponding to an estimated polysaccharide concentration of 0.85 microg/ml. The lowest mean blood antigen concentration found ultrasonically was 0.05 microg/ml; compared to the 1.98 microg/ml found by conventional latex agglutination, this represents an approximately 30-fold improvement in sensitivity. Three grades of outcome were correlated with the presenting antigen titre in 83 patients: (i) <2 weeks hospitalisation, (ii) > or =2 weeks hospitalisation and (iii) mortality. High polysaccharide concentrations correlated with mortality. Nine of 15 patients with a serum antigen titre of 1/64 or greater (> or =3.4 microg/ml polysaccharide) died, whereas no patient with titres equal to or less than 1/4 (< or = 0.21 microg/ml) died, including those patients in whom antigen was undetectable by ultrasonic immunoassay. Increasing antigen concentration significantly correlated with severity of outcome (P<0.001). Ultrasound-enhanced agglutination provides a rapid prognostic indicator by sensitive measurement of serum antigen level.

Для цитирования: Sobanski M A, Barnes R A, Gray S J, Carr A D, Kaczmarski E B, O'Rourke A, Murphy K, Cafferkey M, Ellis R W, Pidcock K, Hawtin P, Coakley W T. Measurement of serum antigen concentration by ultrasound-enhanced immunoassay and correlation with clinical outcome in meningococcal disease.. European journal of clinical microbiology & infectious diseases : official publication of the European Society of Clinical Microbiology. 2000. DOI: 10.1007/s100960050473.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.