Spincare System Demonstrates Safety and Efficacy in Treating Partial-Thickness Burns.

Haik Josef, Ullmann Yehuda, Gur Eyal, Biros Erik, Kornhaber Rachel, Cleary Michelle, Kruchevsky Dani, Zissman Sivan, Namir Yossi, Harats Moti

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Partial-thickness burns are the most common form of burns, affecting the dermis and possibly resulting in scarring and infection. The Spincare System is a new device that uses electrospinning technology to create a temporary skin-like matrix that can be applied to wounds. This study evaluated the performance, safety, and efficacy of Spincare in treating superficial to partial-thickness burns not considered for surgery. A prospective single-arm, open-label, multicenter study was conducted in 3 adult burn units across Israel. Forty-four patients with superficial to intermediate burns of up to 10% of TBSA were enrolled. Spincare was applied to the wounds, and follow-up visits were performed on days 7, 14, and 21 and months 3 and 6 posttreatment. Thirty-one patients with 36 wounds completed the day 21 visit. The mean wound healing area on day 21 was 97.26 ± 9.41%, and the mean healing time was 12.8 ± 4.3 days. Only one moderate adverse event was observed concerning the treatment, and it is important to acknowledge the potential progression of this hypertrophic scar into a keloid. This study demonstrated that Spincare is a safe and effective device for treating superficial to intermediate partial-thickness burns. Spincare achieved rapid and complete wound healing with a low incidence of adverse events.

Для цитирования: Haik Josef, Ullmann Yehuda, Gur Eyal, Biros Erik, Kornhaber Rachel, Cleary Michelle, Kruchevsky Dani, Zissman Sivan, Namir Yossi, Harats Moti. Spincare System Demonstrates Safety and Efficacy in Treating Partial-Thickness Burns.. Journal of burn care & research : official publication of the American Burn Association. 2024. DOI: 10.1093/jbcr/irae024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.