MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1128/aac.00932-23

Медицинская библиотека · Antimicrobial agents and chemotherapy · 2023

Simplified urine-based method to detect rifampin underexposure in adults with tuberculosis: a prospective diagnostic accuracy study.

Xie Yingda L, Modi Nisha, Handler Deborah, Yu Sijia, Rao Prakruti, Kagan Leonid, Petros de Guex Kristen, Reiss Robert, Siemiątkowska Anna, Narang Anshika, Narayanan Navaneeth, Hearn Jasie, Khalil Amanda, Woods Patricia, Young Laura, Lardizabal Alfred, Subbian Selvakumar, Peloquin Charles A, Vinnard Christopher, Thomas Tania A, Heysell Scott K

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Variable pharmacokinetics of rifampin in tuberculosis (TB) treatment can lead to poor outcomes. Urine spectrophotometry is simpler and more accessible than recommended serum-based drug monitoring, but its optimal efficacy in predicting serum rifampin underexposure in adults with TB remains uncertain. Adult TB patients in New Jersey and Virginia receiving rifampin-containing regimens were enrolled. Serum and urine samples were collected over 24 h. Rifampin serum concentrations were measured using validated liquid chromatography-tandem mass spectrometry, and total exposure (area under the concentration-time curve) over 24 h (AUC0-24) was determined through noncompartmental analysis. The Sunahara method was used to extract total rifamycins, and rifampin urine excretion was measured by spectrophotometry. An analysis of 58 eligible participants, including 15 (26%) with type 2 diabetes mellitus, demonstrated that urine spectrophotometry accurately identified subtarget rifampin AUC0-24 at 0-4, 0-8, and 0-24 h. The area under the receiver operator characteristic curve (AUC ROC) values were 0.80 (95% CI 0.67-0.90), 0.84 (95% CI 0.72-0.94), and 0.83 (95% CI 0.72-0.93), respectively. These values were comparable to the AUC ROC of 2 h serum concentrations commonly used for therapeutic monitoring (0.82 [95% CI 0.71-0.92], P = 0.6). Diabetes status did not significantly affect the AUC ROCs for urine in predicting subtarget rifampin serum exposure (P = 0.67-0.92). Spectrophotometric measurement of urine rifampin excretion within the first 4 or 8 h after dosing is a simple and cost-effective test that accurately predicts rifampin underexposure. This test provides critical information for optimizing tuberculosis treatment outcomes by facilitating appropriate dose adjustments.

Для цитирования: Xie Yingda L, Modi Nisha, Handler Deborah, Yu Sijia, Rao Prakruti, Kagan Leonid, Petros de Guex Kristen, Reiss Robert, Siemiątkowska Anna, Narang Anshika, Narayanan Navaneeth, Hearn Jasie, Khalil Amanda, Woods Patricia, Young Laura, Lardizabal Alfred, Subbian Selvakumar, Peloquin Charles A, Vinnard Christopher, Thomas Tania A, Heysell Scott K. Simplified urine-based method to detect rifampin underexposure in adults with tuberculosis: a prospective diagnostic accuracy study.. Antimicrobial agents and chemotherapy. 2023. DOI: 10.1128/aac.00932-23.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.