MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0360-3016(94)00599-g

Медицинская библиотека · International journal of radiation oncology, biology, physics · 1995

Dosimetry guidelines to minimize urethral and rectal morbidity following transperineal I-125 prostate brachytherapy.

Wallner K, Roy J, Harrison L

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To establish dosimetry guidelines to minimize urethral and rectal morbidity following permanent I-125 prostatic brachytherapy.

METHODS AND MATERIALS: Dosimetric parameters were correlated with long-term morbidity for 65 patients following transperineal I-125 implantation for Stage T1/T2 prostatic carcinoma. The prescribed minimum prostatic dose was 150 Gy. The median total activity used was 48 mCi (range: 32-77 mCi). Patients were followed for 1-5 years (median follow-up: 2 years). Postimplant computerized tomography (CT)-based dosimetry was performed for 45 patients. Morbidity was evaluated using a modification of the RTOG grading system, with a scale of grade 0-5.

RESULTS

The incidence of grades 2 and 3 urinary morbidity was associated with the maximum central urethral dose (p = 0.03), and with the length of urethra that received greater than 400 Gy (p = 0.07). Patients with larger prostates had more long-term urinary morbidity (p = 0.06). Rectal bleeding (RTOG grade 1) or ulceration (RTOG grade 2) was associated with irradiation of the rectal wall to doses in excess of 100 Gy (p = 0.02). There was no relationship between the matched peripheral dose (MPD), mCi/source or total mCi implanted and long-term morbidity.

CONCLUSIONS

Postimplant, CT-based dosimetry can predict which patients are at higher risk of radiation-related morbidity. More simplistic parameters including the MPD, total activity implanted, or mCi/source, had no relationship with morbidity. To decrease the risk of long-term morbidity, an effort should be made to keep the central urethral dose below 400 Gy, and the rectal surface dose below 100 Gy.

Для цитирования: Wallner K, Roy J, Harrison L. Dosimetry guidelines to minimize urethral and rectal morbidity following transperineal I-125 prostate brachytherapy.. International journal of radiation oncology, biology, physics. 1995. DOI: 10.1016/0360-3016(94)00599-g.