DOI 10.1016/j.jogc.2023.02.017
Vacuum-Induced Hemorrhage Control versus Uterine Balloon Tamponade for Postpartum Hemorrhage.
Аннотация
OBJECTIVE
To compare maternal outcomes of uterine balloon tamponade (UBT) versus an intrauterine vacuum-induced hemorrhage control device (VHD) for the management of primary postpartum hemorrhage (PPH).
METHODS
Retrospective cohort of all patients with PPH due to uterine atony treated with an intrauterine device within a university health system from January 2019 to June 2021. The primary outcome of massive transfusion, defined as PPH requiring transfusion of ≥4 units of packed red blood cells (PRBC), was compared between 2 groups: UBT (n = 78) versus VHD (n = 36). Statistical analysis included the use of chi-squared and Wilcoxon rank sum tests with statistical significance set at P < 0.05.
RESULTS
Baseline characteristics were similar between the 2 groups. The proportion of patients who received ≥4 units of PRBC was significantly lower in the VHD group compared to the UBT group (2.8% vs. 20.5%, P = <0.01). The proportion of patients who were transfused ≥2 units of PRBC and median estimated blood loss (EBL) were also both significantly lower in the VHD group compared to the UBT group (36.1% vs. 57.7%, P = < 0.01, and 1 500 mL vs. 1 875 mL, P = 0.02, respectively). Rates of other secondary outcomes were similar between the 2 groups.
CONCLUSION
Our data suggest that the use of intrauterine VHD in the management of PPH is associated with a lower number of massive transfusions and EBL compared to UBT. Randomized controlled trials are needed before drawing definitive conclusions on which device is more effective in this setting.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.