European thyroid journal · 2020
Macro-TSH: A Diagnostic Challenge.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Larsen Camilla Bøgelund, Petersen Eva Rabing Brix, Overgaard Martin, Bonnema Steen Joop
Аннотация
INTRODUCTION: Analytical problems should be considered in case of a discrepancy between the results of biochemical tests and the clinical findings. Macro-hormones often artefactually elevate biochemical tests.
CASE PRESENTATION: A young male was referred with persistently elevated TSH (148 mIU/L) measured by a sandwich electrochemiluminescence immunoassay, ECLIA (Cobas; Roche, Basel, Switzerland). The patient's complaints were unspecific, and he appeared clinically euthyroid. The plasma levels of free T4 and free T3 were within the normal range, thyroid autoantibodies were negative, and thyroid ultrasonography was normal. During a short trial of thyroid hormone substitution, the level of TSH decreased to near-normal levels, but hyperthyroid symptoms emerged. TSH analysed by a different immunoassay (Architect; Abbott, Chicago, IL, USA) yielded similar results. In addition, serial dilutions were performed showing linearity, without detection of heterophilic antibody interference. Gel filtration chromatography confirmed the presence of macro-TSH.
CONCLUSION: The patient harboured macro-TSH, which is a rare condition. The complex binding of TSH to other plasma proteins, most often immunoglobulins, results in elevated plasma TSH. However, the biologically active fraction of TSH is normal, reflected by clinical and biochemical euthyroidism.
CASE PRESENTATION: A young male was referred with persistently elevated TSH (148 mIU/L) measured by a sandwich electrochemiluminescence immunoassay, ECLIA (Cobas; Roche, Basel, Switzerland). The patient's complaints were unspecific, and he appeared clinically euthyroid. The plasma levels of free T4 and free T3 were within the normal range, thyroid autoantibodies were negative, and thyroid ultrasonography was normal. During a short trial of thyroid hormone substitution, the level of TSH decreased to near-normal levels, but hyperthyroid symptoms emerged. TSH analysed by a different immunoassay (Architect; Abbott, Chicago, IL, USA) yielded similar results. In addition, serial dilutions were performed showing linearity, without detection of heterophilic antibody interference. Gel filtration chromatography confirmed the presence of macro-TSH.
CONCLUSION: The patient harboured macro-TSH, which is a rare condition. The complex binding of TSH to other plasma proteins, most often immunoglobulins, results in elevated plasma TSH. However, the biologically active fraction of TSH is normal, reflected by clinical and biochemical euthyroidism.