Mechanical circulatory assist devices stroke subtype classification: a novel stroke classification system in patients with ventricular assist devices.

Pinto Camila Bonin, Owens Cameron D, Alvarado-Dyer Ronald, Loggini Andrea, Ortiz-Garcia Jorge, Heldner Mirjam R, Prabhakaran Shyam, Saleh Velez Faddi G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Stroke is a frequent complication of left ventricular assist devices (LVADs) yet remains without a unified etiologic framework to guide evaluation and management. To address this, we developed a novel mechanical circulatory assist device stroke classification system with four etiologic categories: Management-related (M)-events driven by anticoagulation/antiplatelet strategy or perioperative management; Clinically related (C)-events attributable to conventional vascular risk factors; Acquired (A)-events resulting from LVAD-associated complications such as infection or coagulopathy; and Device-related (D)-events linked to pump- or graft-specific pathology or parameter abnormalities. We aimed to describe stroke subtype patterns and evaluate interrater reliability of this classification in LVAD patients.

METHODS

We retrospectively reviewed 192 LVAD recipients at the University of Chicago Medical Center (2010-2020) and identified 32 neuroimaging-confirmed cerebrovascular events. Clinical characteristics, stroke subtype, contributing mechanisms, and outcomes were recorded. Two independent vascular neurologists classified each event using the MCAD system, and interrater reliability was assessed using intraclass correlation coefficients (ICC).

RESULTS

Among the 32 cerebrovascular events, 59.4% were ischemic and 40.6% hemorrhagic (25% intraparenchymal, 12.5% subarachnoid). Strokes occurred a mean of 27 months after LVAD implantation. Strokes were categorized as Management-related (62.6%), Acquired (15.6%), Device-related (15.6%), and Clinically related (6.2%). Interrater agreement was excellent (ICC = 0.974).

CONCLUSION

This novel MCAD stroke classification demonstrated excellent interrater reliability in a single-center LVAD retrospective cohort and provides a structured framework for categorizing etiologic contributors. Future prospective multicenter studies are needed to assess its clinical utility.

Для цитирования: Pinto Camila Bonin, Owens Cameron D, Alvarado-Dyer Ronald, Loggini Andrea, Ortiz-Garcia Jorge, Heldner Mirjam R, Prabhakaran Shyam, Saleh Velez Faddi G. Mechanical circulatory assist devices stroke subtype classification: a novel stroke classification system in patients with ventricular assist devices.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2026. DOI: 10.1016/j.jstrokecerebrovasdis.2026.108605.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.