BACKGROUND

Endoscopic piriformis release (EPR) is among the available treatments for piriformis syndrome. This procedure typically involves dividing the muscle near the sciatic nerve in the sub-gluteal space, which contains numerous blood vessels and nerves. The objectives of this prospective cadaver study were: 1) to assess the reproducibility and quality of endoscopic piriformis tenotomy near the greater trochanter; 2) to detect iatrogenic injuries to the lateral hip rotators, nerves, and vessels; 3) and to define the surgical safety margins relative to the sciatic nerve and inferior gluteal bundle.

HYPOTHESIS: EPR at the greater trochanter ensures full release of the muscle with a limited risk of neuro-vascular injury.

MATERIAL AND

METHODS

EPR was performed via two portals on 10 cadaver hips preserved in zinc chloride and placed in the prone position. A third, ancillary portal was required in 7 cases. The area was then dissected with the Kocher-Langenbeck approach to allow an assessment of the tenotomy, detect iatrogenic injuries, and measure the distances separating the tenotomy site from the sciatic nerve and inferior gluteal artery.

RESULTS

Complete tenotomy was achieved in 9 (90%) cases. The tendon adhered to the capsule in 2 (20%) cases and showed acquired avulsion in 1 case. No injuries to the sciatic nerve or inferior gluteal artery occurred. Mean distances from the tenotomy site were 5.21±0.59cm (range, 4.5-6.6cm) for the sciatic nerve and 7.1±0.89cm (range, 5.4-8.5cm) for the inferior gluteal artery.

DISCUSSION: EPR by a tenotomy at the greater trochanter without sciatic nerve release provides full release of the muscle with satisfactory safety margins and a short learning curve.

LEVEL OF EVIDENCE: III, prospective cadaver case-control study.

Для цитирования: Coulomb Rémy, Khelifi Anis, Bertrand Martin, Mares Olivier, May Olivier, Marchand Philippe, Kouyoumdjian Pascal. Does endoscopic piriformis tenotomy provide safe and complete tendon release? A cadaver study.. Orthopaedics & traumatology, surgery & research : OTSR. 2018. DOI: 10.1016/j.otsr.2018.02.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.