DOI 10.1186/s40981-026-00864-6
Refractory anaphylactic shock complicated by acute right heart failure during anesthetic induction in a patient with a left ventricular assist device: a case report.
Аннотация
BACKGROUND
Anaphylaxis in patients with a left ventricular assist device (LVAD) may critically reduce LVAD flow, particularly when the right ventricular function is impaired.
CASE PRESENTATION: A 51-year-old man with a HeartMate III LVAD developed bronchospasm, profound hypotension, and decreased LVAD flow during anesthetic induction for endoscopic sinus surgery. The shock remained refractory despite epinephrine boluses and continuous infusions of epinephrine, norepinephrine, and vasopressin. Transesophageal echocardiography revealed severe right ventricular dilatation, leftward septal shift, and reduced left ventricular size, findings consistent with acute right heart failure (RHF). Treatment was escalated to include dobutamine, olprinone, and inhaled nitric oxide, achieving recovery of blood pressure and LVAD flow. Elevated serum tryptase supported the diagnosis of anaphylaxis, and a positive intradermal test identified remimazolam as the cause.
CONCLUSIONS
Successful anaphylaxis management in LVAD recipients may require rapid recognition and treatment of acute RHF in addition to standard treatment including epinephrine.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.