m+Medelevator.RU
← Поиск публикаций
Interdisciplinary cardiovascular and thoracic surgery · 2024

Alternative venous access sites for dual-lumen extracorporeal membrane oxygenation cannulation.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Schoeberl Armin-Kai, Staudacher Dawid, Kawashima Mitsuaki, Fischer Courtney, Cypel Marcelo, Buchtele Nina, Staudinger Thomas, Aigner Clemens, Hoetzenecker Konrad, Schweiger Thomas

Аннотация

OBJECTIVES: Dual-lumen cannulas for veno-venous (VV) extracorporeal membrane oxygenation (ECMO) support are typically inserted in the right internal jugular vein (RIJV); however, some scenarios can make this venous route inaccessible. This multicentre case series aims to evaluate if single-site cannulation using an alternative venous access is safe and feasible in patients with an inaccessible RIJV.

METHODS: We performed a multi-institutional retrospective analysis including high-volume ECMO centres with substantial experience in dual-lumen cannulation (DLC) (defined as >10 DLC per year). Three centres [Freiburg (Germany), Toronto (Canada) and Vienna (Austria)] agreed to share their data, including baseline characteristics, technical ECMO and cannulation data as well as complications related to ECMO cannulation and outcome.

RESULTS: A total of 20 patients received alternative DLC for respiratory failure. Cannula insertion sites included the left internal jugular vein (n = 5), the right (n = 7) or left (n = 3) subclavian vein and the right (n = 4) or left (n = 1) femoral vein. The median cannula size was 26 (19-28) French. The median initial target ECMO flow was 2.9 (1.8-3.1) l/min and corresponded with used cannula size and estimated cardiac output. No procedural complications were reported during cannulation and median ECMO runtime was 15 (9-22) days. Ten patients were successfully bridged to lung transplantation (n = 5) or lung recovery (n = 5). Ten patients died during or after ECMO support.

CONCLUSIONS: Alternative venous access sites for single-site dual-lumen catheters are a safe and feasible option to provide veno-venous ECMO support to patients with inaccessible RIJV.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты