m+Medelevator.RU
← Поиск публикаций
Journal of visualized experiments : JoVE · 2026

Four-Hour Hemoperfusion with Stepwise Blood Flow Rates for Toxin Clearance and Safety in Hemodialysis Patients: A Randomized Controlled Trial.

СтатьяVideo-Audio MediaРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yang Anxiu, Liu Cheng, Qin Xiu, Yang Xue, Wang Xuan, Ren Xizhu, Sun Wei, Xiong Yaling, Yang Qi

Аннотация

Optimal hemoperfusion (HP) parameters combined with hemodialysis (HD) for removing middle-molecule and protein-bound toxins remain undefined. This prospective randomized controlled trial investigated the effects of extending HP duration and increasing blood flow rate. Eighty-eight maintenance hemodialysis patients were randomized to 2-h or 4-h HP with 4-h HD at 220 mL/min (Phase 1). After a 2-week washout, patients received 4-h HP+HD at 180, 220, or 260 mL/min (Phase 2). Analysis of covariance (ANCOVA) adjusted for baseline imbalances, and linear trend tests evaluated dose-response effects. In Phase 1, the 4-h regimen achieved significantly superior adjusted β2-microglobulin clearance (65.11% ± 4.73% vs. 45.93% ± 4.71%; Adjusted P < 0.001) and reduced loss of hemoglobin and albumin (both P < 0.01). In Phase 2, a significant linear dose-response relationship was observed for all toxins (P for trend < 0.001). A flow rate of 260 mL/min achieved optimal reduction ratios for small molecules and hs-CRP (43.12%). Restricted cubic spline analysis suggested that apparent negative hs-CRP reduction ratios may reflect hemoconcentration-related artifacts (Model P = 0.049). All regimens maintained hemodynamic stability with mean systolic pressure drops of 4.7 ± 24.3 mmHg and 4.2 ± 22.9 mmHg in Phases 1 and 2, respectively. Adverse events were low (0-3.45%) and mild. In conclusion, a 4-h HP session combined with HD, particularly at 260 mL/min, enhances the removal of middle molecules, protein-bound toxins, and inflammatory markers without apparent hemodynamic instability in this single-session study, providing evidence for optimizing operational parameters.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты