The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation · 2024
Surveillance with dual noninvasive testing for acute cellular rejection after heart transplantation: Outcomes from the Surveillance HeartCare Outcomes Registry.
СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Khush Kiran, Hall Shelley, Kao Andrew, Raval Nirav, Dhingra Ravi, Shah Palak, Bellumkonda Lavanya, Ravichandran Ashwin, Van Bakel Adrian, Uriel Nir, Patel Snehal, Pinney Sean, DePasquale Eugene, Baran David A, Pinney Kevin, Oreschak Kris, Kobulnik Jeremy, Shen Ling, Teuteberg Jeffrey
Аннотация
BACKGROUND: Molecular testing with gene-expression profiling (GEP) and donor-derived cell-free DNA (dd-cfDNA) is increasingly used in the surveillance for acute cellular rejection (ACR) after heart transplant. However, the performance of dual testing over each test individually has not been established. Further, the impact of dual noninvasive surveillance on clinical decision-making has not been widely investigated.
METHODS: We evaluated 2,077 subjects from the Surveillance HeartCare Outcomes Registry registry who were enrolled between 2018 and 2021 and had verified biopsy data and were categorized as dual negative, GEP positive/dd-cfDNA negative, GEP negative/dd-cfDNA positive, or dual positive. The incidence of ACR and follow-up testing rates for each group were evaluated. Positive likelihood ratios (LRs+) were calculated, and biopsy rates over time were analyzed.
RESULTS: The incidence of ACR was 1.5% for dual negative, 1.9% for GEP positive/dd-cfDNA negative, 4.3% for GEP negative/dd-cfDNA positive, and 9.2% for dual-positive groups. Follow-up biopsies were performed after 8.8% for dual negative, 14.2% for GEP positive/dd-cfDNA negative, 22.8% for GEP negative/dd-cfDNA positive, and 35.4% for dual-positive results. The LR+ for ACR was 1.37, 2.91, and 3.90 for GEP positive, dd-cfDNA positive, and dual-positive testing, respectively. From 2018 to 2021, biopsies performed between 2 and 12-months post-transplant declined from 5.9 to 5.3 biopsies/patient, and second-year biopsy rates declined from 1.5 to 0.9 biopsies/patient. At 2 years, survival was 94.9%, and only 2.7% had graft dysfunction.
CONCLUSIONS: Dual molecular testing demonstrated improved performance for ACR surveillance compared to single molecular testing. The use of dual noninvasive testing was associated with lower biopsy rates over time, excellent survival, and low incidence of graft dysfunction.
METHODS: We evaluated 2,077 subjects from the Surveillance HeartCare Outcomes Registry registry who were enrolled between 2018 and 2021 and had verified biopsy data and were categorized as dual negative, GEP positive/dd-cfDNA negative, GEP negative/dd-cfDNA positive, or dual positive. The incidence of ACR and follow-up testing rates for each group were evaluated. Positive likelihood ratios (LRs+) were calculated, and biopsy rates over time were analyzed.
RESULTS: The incidence of ACR was 1.5% for dual negative, 1.9% for GEP positive/dd-cfDNA negative, 4.3% for GEP negative/dd-cfDNA positive, and 9.2% for dual-positive groups. Follow-up biopsies were performed after 8.8% for dual negative, 14.2% for GEP positive/dd-cfDNA negative, 22.8% for GEP negative/dd-cfDNA positive, and 35.4% for dual-positive results. The LR+ for ACR was 1.37, 2.91, and 3.90 for GEP positive, dd-cfDNA positive, and dual-positive testing, respectively. From 2018 to 2021, biopsies performed between 2 and 12-months post-transplant declined from 5.9 to 5.3 biopsies/patient, and second-year biopsy rates declined from 1.5 to 0.9 biopsies/patient. At 2 years, survival was 94.9%, and only 2.7% had graft dysfunction.
CONCLUSIONS: Dual molecular testing demonstrated improved performance for ACR surveillance compared to single molecular testing. The use of dual noninvasive testing was associated with lower biopsy rates over time, excellent survival, and low incidence of graft dysfunction.