MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1010-7940(01)00818-1

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2001

Pulmonary function testing after operative stabilisation of the chest wall for flail chest.

Lardinois D, Krueger T, Dusmet M, Ghisletta N, Gugger M, Ris H B

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This is a prospective evaluation of chest wall integrity and pulmonary function in patients with operative stabilisation for flail chest injuries.

METHODS

From 1990 to 1999, 66 patients (56 men, 10 women; mean age 52.6 years) with antero-lateral flail chest (> or =4 ribs fractured at > or =2 sites) underwent surgical stabilisation using reconstruction plates. Clinical assessment and pulmonary function testing were performed at 6 months following surgery.

RESULTS

Fifty-five (83%) patients had various combinations of injuries of the thorax, head, abdomen and extremities. Sixty-three (95.5%) patients underwent unilateral and 3 (4.5%) patients bilateral stabilisation with a median delay of 2.8 days (range 0-21 days) from admission. The 30-day mortality was 11% (seven of 66 patients). Immediate postoperative extubation was feasible in 31 of 66 patients (47%) and extubation within 7 days following stabilisation in 56 of 66 patients (85%). No plate dislocation was observed during the follow-up. The shoulder girdle function was intact in 51 of 57 patients (90%). Chest wall complaints were noted in 6 of 57 (11%) patients, requiring removal of implants in three cases. All patients returned to work within a mean period of 8 (range 3-16) weeks following discharge. Pulmonary function testing (n=50) at 6 months after the operation revealed a significant difference of predicted vs. recorded vital capacity (VC) and forced expiratory volume in 1s (FEV1) (P=0.04 and P=0.0001, respectively; Wilcoxon signed-rank test). The median ratio of the recorded and predicted total lung capacity (TLC) was shown to be significantly higher than 0.85 (P=0.0002; Wilcoxon signed-rank test), indicating prevention of pulmonary restriction.

CONCLUSION

Antero-lateral flail chest injuries accompanied by respiratory insufficiency can be effectively stabilised using reconstruction plates. Early restoration of the chest wall integrity and respiratory pump function may be cost effective through the prevention of prolonged mechanical ventilation and restriction-related working incapacity.

Для цитирования: Lardinois D, Krueger T, Dusmet M, Ghisletta N, Gugger M, Ris H B. Pulmonary function testing after operative stabilisation of the chest wall for flail chest.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2001. DOI: 10.1016/s1010-7940(01)00818-1.