DOI 10.1016/j.jvir.2013.02.019

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2013

Primary percutaneous treatment of transplant ureteral strictures using tandem stents.

Kriegshauser J Scott, Naidu Sailen G, Heilman Raymond L, Huettl Eric A, Ferlic Elisabeth A, Castle Erik P, Hentz Joseph G

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate outcomes of primary (first-occurrence) treatment of renal transplant ureteral strictures using tandem parallel internal double-pigtail stents.

MATERIALS AND

METHODS

A retrospective electronic chart review, including demographics, medical history, stricture intervention, and outcomes, was performed of patients with renal transplants with first-occurrence ureteral obstructions or leaks reported in a transplant nephrology database over a 4-year period, with a focus on patients treated primarily with tandem stents.

RESULTS

Of 27 patients with first-occurrence ureteral obstruction or ureteral leak, 18 (67%) were treated primarily using tandem internal stents, with 15 (83%) of 18 stent-free for a minimum 90 days of follow-up. There was no significant difference between outcomes for male versus female patients (P>.99) or early versus late strictures (P = .53). Urinary tract infections (UTIs) occurred in 14 (78%) of 18 patients with tandem stents in place. Four patients were hospitalized<48 hours with UTI and sepsis; there were no other major complications.

CONCLUSIONS

Patients with renal transplants can be successfully managed nonsurgically using tandem ureteral stents for the primary treatment of first-occurrence ureteral stricture. These patients may require more intensive monitoring for UTIs.

Для цитирования: Kriegshauser J Scott, Naidu Sailen G, Heilman Raymond L, Huettl Eric A, Ferlic Elisabeth A, Castle Erik P, Hentz Joseph G. Primary percutaneous treatment of transplant ureteral strictures using tandem stents.. Journal of vascular and interventional radiology : JVIR. 2013. DOI: 10.1016/j.jvir.2013.02.019.