MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2019.07.016

Медицинская библиотека · American journal of ophthalmology · 2019

Corneal Endothelial Cell Loss and Morphometric Changes 5 Years after Phacoemulsification with or without CyPass Micro-Stent.

Lass Jonathan H, Benetz Beth Ann, He Jonathan, Hamilton Cody, Von Tress Mark, Dickerson Jaime, Lane Stephen

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To characterize long-term changes in corneal endothelial cells after phacoemulsification with or without supraciliary Micro-Stent (Alcon) implantation in eyes with open-angle glaucoma (OAG) and visually significant cataract.

DESIGN

Three-year safety extension of a 2-year randomized clinical trial.

METHODS

Patients from the multicenter Study of an Implantable Device for Lowering Intraocular Pressure in Glaucoma Patients Undergoing Cataract Surgery (COMPASS) trial who underwent Micro-Stent implantation plus phacoemulsification (n = 282) or phacoemulsification alone (n = 67) were analyzed post hoc. Specular microscopy was used to assess endothelial cell loss (ECL), including changes from baseline in endothelial cell density (ECD), coefficient of variation, and percentage of hexagonal cells.

RESULTS

Preoperative ECDs in the microstent group (2,432.6 cells/mm2 [95% confidence interval [CI], 2,382.8-2,482.4 cells/mm2]) were similar to those in the control group (2,434.5 cells/mm2 [95% CI, 2,356.5-2,512.4 cells/mm2]) groups. ECL at months 48 and 60 was greater in the Micro-Stent group than in the control group. At month 60, the mean percent of changes in ECD was -20.4% (95% CI, -23.5% to -17.5%) in the Micro-Stent group and -10.1% (95% CI, -13.9% to -6.3%) in the control group. No statistically significant between-group changes from baseline in cellular morphology were observed. Nine adverse events were possibly related to ECL, including 3 eyes with transient focal corneal edema and 4 eyes that required Micro-Stent trimming due to protrusion.

CONCLUSIONS

In eyes with OAG, ECL after phacoemulsification is acute and stabilizes after 3 months, whereas ECL after phacoemulsification plus Micro-Stent implantation proceeds for at least 5 years. Clinical findings associated with ECL in these eyes were uncommon (3.3% of implanted eyes), suggesting that ECL is generally a subclinical phenomenon.

Для цитирования: Lass Jonathan H, Benetz Beth Ann, He Jonathan, Hamilton Cody, Von Tress Mark, Dickerson Jaime, Lane Stephen. Corneal Endothelial Cell Loss and Morphometric Changes 5 Years after Phacoemulsification with or without CyPass Micro-Stent.. American journal of ophthalmology. 2019. DOI: 10.1016/j.ajo.2019.07.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.