Deep learning-driven abbreviated knee MRI protocols: diagnostic accuracy in clinical practice.

Foti Giovanni, Spoto Flavio, Spezia Alessandro, Romano Luigi, Caia Simone, Camerani Francesco, Benedetti Damiano, Mignolli Thomas

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Deep learning (DL) reconstruction shows potential in reducing MRI acquisition times while preserving image quality, but the impact of varying acceleration factors on knee MRI diagnostic accuracy remains undefined.

PURPOSE: Evaluate diagnostic performance of twofold, fourfold, and sixfold DL-accelerated knee MRI protocols versus standard protocols.

MATERIALS/

METHODS

In this prospective study, 71 consecutive patients underwent knee MRI with standard, DL2, DL4, and DL6 accelerated protocols. Four radiologists assessed ligament tears, meniscal lesions, bone marrow edema, chondropathy, and extensor abnormalities. Sensitivity, specificity, and interobserver agreement were calculated.

RESULTS

DL2 and DL4 demonstrated high diagnostic accuracy. For ACL tears, DL2/DL4 achieved 98-100% sensitivity/specificity, while DL6 showed reduced sensitivity (91-96%). In meniscal evaluation, DL2 maintained 96-100% sensitivity and 98-100% specificity; DL4 showed 94-98% sensitivity and 97-99% specificity. DL6 exhibited decreased sensitivity (82-92%) for subtle lesions. Bone marrow edema detection remained excellent across acceleration factors. Interobserver agreement was excellent for DL2/DL4 (W = 0.91-0.97) and good for DL6 (W = 0.78-0.89).

CONCLUSION

DL2 protocols demonstrate performance nearly identical to standard protocols, while DL4 maintains acceptable diagnostic accuracy for most pathologies. DL6 shows reduced sensitivity for subtle abnormalities, particularly among less experienced readers. DL2 and DL4 protocols represent optimal balance between acquisition time reduction (50-75%) and diagnostic confidence.

Для цитирования: Foti Giovanni, Spoto Flavio, Spezia Alessandro, Romano Luigi, Caia Simone, Camerani Francesco, Benedetti Damiano, Mignolli Thomas. Deep learning-driven abbreviated knee MRI protocols: diagnostic accuracy in clinical practice.. La Radiologia medica. 2025. DOI: 10.1007/s11547-025-02038-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.