MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/tme.12982

Медицинская библиотека · Transfusion medicine (Oxford, England) · 2023

Plasma exchange in acute hemolytic reaction due to ABO-incompatible erythrocyte concentrate transfusions: Single center experience.

Andıç Neslihan, Teke Hava Üsküdar, Gündüz Eren

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVES

Acute hemolytic transfusion reaction (AHTR) due to ABO-incompatible erythrocyte concentrate (EC) is one of the most catastrophic complications of transfusion. Since the hemolysis is intravascular; hemoglobinemia and hemoglobinuria result in disseminated intravascular coagulation (DIC), acute renal failure, shock, and sometimes death.

BACKGROUND

Treatment of AHTR is mostly supportive measures. Today there are no clear suggestions about plasma exchange (PE) in these patients.

METHODS/MATERIALS: Here we report our experience with six patients diagnosed with AHTR due to ABO-incompatible EC transfusion.

RESULTS

We performed PE in 5 of these patients. Although all of our patients were geriatric and most of them had significant comorbidities four out of five patients recovered without an incident.

CONCLUSION

Although PE is considered a last-chance treatment when other measures fail in the literature, our experience above indicates that it must be evaluated in every patient with AHTR early in the course. If the patient has cardiac and renal comorbidities, large volume EC is transfused, DAT is negative, plasma color is red and there is macroscopic hemoglobinuria, we suggest performing PE.

Для цитирования: Andıç Neslihan, Teke Hava Üsküdar, Gündüz Eren. Plasma exchange in acute hemolytic reaction due to ABO-incompatible erythrocyte concentrate transfusions: Single center experience.. Transfusion medicine (Oxford, England). 2023. DOI: 10.1111/tme.12982.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.