MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/17585732261489263

Медицинская библиотека · Shoulder & elbow · 2026

Clinical and radiographic outcomes of reverse shoulder arthroplasty performed with 40 mm polyethylene glenospheres vs. 36 mm cobalt chrome glenospheres at minimum 2-years follow-up.

Boekel Pamela, Piggott Robert P, Conyard Christopher, Bale Stephen, Walton Michael, Monga Puneet, Malhas Amar, Trail Ian A

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Most reverse total shoulder arthroplasty utilise a cobalt chrome (CoCr) glenosphere with a polyethylene liner. The Lima Shoulder Modular Replacement (SMR)™ platform has inverted the materials to potentially decrease polyethylene debris when the humeral liner contacts the scapula.

METHODS

This retrospective, multi-centre study was conducted to examine the equivalence of the Lima SMR™ 40 mm highly cross-linked polyethylene (XLPE) glenospheres to the 36 mm CoCr glenospheres, examining patients from 2013 to 2022 with a minimum of 2-year clinical and radiographic follow-up.

RESULTS

199 patients were investigated: 107 with the XLPE glenosphere and 92 with the CoCr glenosphere. At 2-year follow-up, there was no significant difference in Oxford Shoulder scores (p = 0.081). There were more areas of glenoid radiolucency in the CoCr group (n = 18 zones in eight patients) at 2 years (z = -2.04, p = 0.04). There was no significant difference in notching (16% in the XLPE group, 20% in CoCr group (p = 0.190)). Two patients in the XLPE group were revised and five in the CoCr group.

DISCUSSION: XLPE glenosphere outcomes were largely equivalent to a CoCr glenosphere at 2 years. While the XLPE glenosphere had fewer major complications, this could be attributed to other factors including the larger diameter, rather than the polyethylene glenosphere.

LEVEL OF EVIDENCE: Level III - retrospective comparative study.

Для цитирования: Boekel Pamela, Piggott Robert P, Conyard Christopher, Bale Stephen, Walton Michael, Monga Puneet, Malhas Amar, Trail Ian A. Clinical and radiographic outcomes of reverse shoulder arthroplasty performed with 40 mm polyethylene glenospheres vs. 36 mm cobalt chrome glenospheres at minimum 2-years follow-up.. Shoulder & elbow. 2026. DOI: 10.1177/17585732261489263.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.