Dyssynchrony and Response to Cardiac Resynchronization Therapy in Heart Failure Patients With Unfavorable Electrical Characteristics.

Layec Jeremy, Decroocq Marie, Delelis Francois, Appert Ludovic, Guyomar Yves, Riolet Clémence, Dumortier Hélène, Mailliet Amandine, Tribouilloy Christophe, Maréchaux Sylvestre, Menet Aymeric

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Among heart failure (HF) patients undergoing cardiac resynchronization therapy (CRT), those with unfavorable electrical characteristics (UEC) are less frequently CRT responders.

OBJECTIVES

In this study, the authors sought to evaluate the relationship between preprocedural echocardiographic parameters of electromechanical dyssynchrony (EMD) and outcome following CRT.

METHODS

Among 551 patients receiving CRT, 121 with UEC, defined as atypical left bundle branch, presence of right bundle branch block, or unspecified intraventricular conduction disturbance, were enrolled. Indices of EMD were presence of septal flash, apical rocking, septal deformation patterns, and global wasted work (GWW), determined with the use of speckle-tracking strain echocardiography. Endpoints were response to CRT, defined as a relative decrease in left ventricular end-systolic volume ≥15% at 9-month postoperative follow-up, and all-cause death or HF hospitalization during follow-up.

RESULTS

Among the 121 patients, 68 (56%) were CRT responders. In multivariate analysis, GWW ≥200 mm Hg% (adjusted odds ratio [aOR]: 4.17 [95% CI: 1.33-14.56]; P = 0.0182) and longitudinal strain septal contraction patterns 1 and 2 (aOR: 10.05 [95% CI: 2.82-43.97]; P < 0.001) were associated with CRT response. During a 46-month follow-up (IQR: 42-55 months), survival free from death or HF hospitalization increased with the number of positive criteria (87% for 2, 59% for 1, and 27% for 0). After adjustment for established predictors of outcome in patients receiving CRT, absence of either of the 2 criteria remained associated with a considerable increased risk of death and/or HF hospitalization (adjusted HR: 4.83 [95% CI: 1.84-12.68]; P = 0.001).

CONCLUSIONS

In patients with UEC, echocardiographic assessment of EMD may help to select patients who will derive benefit from CRT. (Echocardiography in Cardiac Resynchronization Therapy [Echo-CRT]; NCT02986633).

Для цитирования: Layec Jeremy, Decroocq Marie, Delelis Francois, Appert Ludovic, Guyomar Yves, Riolet Clémence, Dumortier Hélène, Mailliet Amandine, Tribouilloy Christophe, Maréchaux Sylvestre, Menet Aymeric. Dyssynchrony and Response to Cardiac Resynchronization Therapy in Heart Failure Patients With Unfavorable Electrical Characteristics.. JACC. Cardiovascular imaging. 2023. DOI: 10.1016/j.jcmg.2022.12.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.