MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08820538.2020.1755321

Медицинская библиотека · Seminars in ophthalmology · 2020

Clinical Accuracy of an Advanced Corneal Topographer with Tear-Film Analysis in Functional and Structural Evaluation of Dry Eye Disease.

Lee Jihei Sara, Jun Ikhyun, Kim Eung Kweon, Seo Kyoung Yul, Kim Tae-Im

СтатьяПеревод в очереди

Аннотация

Purpose: Dry eye disease (DED) is a common condition that significantly lowers the quality of life. As the disease grows more prevalent, multiple commercial instruments have been developed to measure the ocular surface of dry eyes, but no single device has yet been successful in comprehensive measurements. The current study aimed to investigate the clinical accuracy and utility of the Antares topographer in the diagnosis of DED.

Methods

Thirty-three consecutive patients underwent analyses of their non-invasive first tear-film break-up time (NIF-BUT), tear meniscus height (TMH) and meibography with the Antares topographer. The meibography with the LipiView scan was conducted. Slit-lamp examinations were done for assessments of meibomian glands (MG) and fluorescein tear-film break-up time (FBUT). Schirmer 1 test was done. The Ocular Surface Disease Index (OSDI) scores were graded.

Results

Thirty-three eyes of 33 patients (mean age 61.5 ± 10.6 years, range 37.5-76.4 years, 27.3% males) completed the study. According to the Antares measurements, the NIF-BUT of the patient population was 5.0 ± 3.4 seconds on average (1.1-15.0 seconds), and the TMH was 0.2 ± 0.1 mm at center (0.1-0.5 mm). The average OSDI score was 22.4 ± 16.6 points (0.0-79.5 points). When correlations were calculated, significant correlations were found between the NIF-BUT from the Antares topographer and FBUT (r = 0.538, P = .001), and between MG dropout from the Antares topographer and that from the LipiView interferometer (r = 0.446, P=.009). Antares NIF BUT and FBUT were in agreement with one another (95% limits of agreement (LOA) -5.04 ± 6.37, P=.198) as were the infrared images from the Antares topographer and those from the LipiView interferometer (95% LOA -0.25 ± 0.35, P=.073).

Conclusion

The Antares topographer is useful in the diagnosis of DED. Among its outputs, the NIF-BUT and MG dropout most closely correlated with currently accepted modes of diagnosis. However, concurrent clinical examinations are recommended for clinical follow-up.

Для цитирования: Lee Jihei Sara, Jun Ikhyun, Kim Eung Kweon, Seo Kyoung Yul, Kim Tae-Im. Clinical Accuracy of an Advanced Corneal Topographer with Tear-Film Analysis in Functional and Structural Evaluation of Dry Eye Disease.. Seminars in ophthalmology. 2020. DOI: 10.1080/08820538.2020.1755321.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.