Non-invasive pressure-volume loop analysis in left ventricular load manipulation.

Pola Karin, Burup Kristensen Charlotte, Watson William D, Green Peregrine G, Raman Betty, Neubauer Stefan, Rider Oliver J, Hassager Christian, Møgelvang Rasmus, Arvidsson Per M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Clinical monitoring of patients with heart failure or cardiomyopathy is facilitated by detailed assessment of cardiac loading conditions. Specifically, alterations in preload and afterload may unmask pathology through effects on ventricular pressure-volume (PV) relations. Therefore, the aim was to assess non-invasive PV loops during left ventricular load manipulation in healthy participants and in patients with hypertrophic cardiomyopathy (HCM).

METHODS

In total, n = 46 participants were studied in paired experiments at baseline and during load manipulation. Controls (n = 24) and patients with HCM (n = 14) were assessed at baseline and during intravenous infusion of 1.5-2 L isotonic saline, and another group of volunteers (n = 8) was assessed at baseline and during infusion of glyceryl trinitrate (GTN). Non-invasive PV loops were calculated from cardiovascular magnetic resonance (CMR) and concurrent brachial blood-pressure measurements.

RESULTS

Saline infusion brought about increased end-diastolic and decreased end-systolic volumes in controls, but not in HCM. Concurrently, PV loops revealed mechanistic differences, where controls but not HCM exhibited decreased arterial elastance and potential energy during load manipulation. In both groups, ventricular-arterial coupling (VAC) decreased, and ventricular efficiency and cardiac output increased. Infusion of GTN resulted in decreased ventricular volumes. Contrary to saline infusion, volunteers receiving GTN retained unchanged arterial elastance, VAC, ventricular efficiency and cardiac output.

CONCLUSION

Non-invasive PV analysis from CMR detects cardiac response to altered loading conditions in healthy participants and in patients with HCM. Our findings support the use of CMR-derived PV loops for detailed assessment of cardiac thermodynamic performance in relation to interventions affecting preload and afterload.

Для цитирования: Pola Karin, Burup Kristensen Charlotte, Watson William D, Green Peregrine G, Raman Betty, Neubauer Stefan, Rider Oliver J, Hassager Christian, Møgelvang Rasmus, Arvidsson Per M. Non-invasive pressure-volume loop analysis in left ventricular load manipulation.. Clinical physiology and functional imaging. 2026. DOI: 10.1111/cpf.70081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.