BACKGROUND

Hemodialysis (HD) access is considered a critical and actionable determinant of morbidity, with a growing literature suggesting that initial HD access type is an important marker of long-term outcomes. Accordingly, we examined HD access during the incident dialysis period, focusing on infection risk and successful fistula creation during the first dialysis year.

STUDY

DESIGN

Longitudinal cohort.

SETTING &

PARTICIPANTS

All US adults admitted to Fresenius Medical Care North America facilities within 15 days of first maintenance dialysis session between January 1 and December 31, 2007.

PREDICTOR: Vascular access type at HD therapy initiation.

OUTCOMES: Vascular access type at 90 days and at the end of the first year on HD therapy, bloodstream infection within the first year by access type, and catheter complication rate.

RESULTS

Of 25,003 incident dialysis patients studied, 19,622 (78.5%) initiated dialysis with a catheter; 4,151 (16.6%), with a fistula; and 1,230 (4.9%), with a graft. At 90 days, 14,105 (69.7%) had a catheter, 4,432 (21.9%) had a fistula, and 1,705 (8.4%) had a graft. Functioning fistulas and grafts at dialysis therapy initiation had first-year failure rates of 10% and 15%, respectively. Grafts were seldom replaced by fistulas (3%), whereas 7,064 (47.6%) of all patients who initiated with a catheter alone still had only a catheter at 1 year. Overall, 3,327 (13.3%) patients had at least one positive blood culture during follow-up, with the risk being similar between the fistula and graft groups, but approximately 3-fold higher in patients with a catheter (P<0.001 for either comparison). Nearly 1 in 3 catheters (32.5%) will require tissue plasminogen activator use by a median of 41 days, with 59% requiring more than one tissue plasminogen activator administration.

LIMITATIONS: Potential underestimation of bacteremia because follow-up blood culture results did not include samples sent to local laboratories.

CONCLUSIONS

In a large and representative population of incident US dialysis patients, catheter use remains very high during the first year of HD care and is associated with high mechanical complication and bloodstream infection rates.

Для цитирования: Xue Hui, Ix Joachim H, Wang Weiling, Brunelli Steven M, Lazarus Michael, Hakim Raymond, Lacson Eduardo. Hemodialysis access usage patterns in the incident dialysis year and associated catheter-related complications.. American journal of kidney diseases : the official journal of the National Kidney Foundation. 2012. DOI: 10.1053/j.ajkd.2012.09.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.