MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-1718-3552

Медицинская библиотека · Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V... · 2022

[Establishing a standardized diagnostic Procedure for sonographic Imaging and Evaluation of the scapholunate Ligament].

Handschak Tino, Hofmann Gunther, Braunschweig Rainer, Tamouridis Georgios, Siemers Frank

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ultrasound has not yet been established in the diagnostic workup of scapholunate ligament lesions. We aimed to develop a standardised examination procedure to visualise and evaluate the SL ligament.

PATIENTS AND

METHODS

Forty patients (70 hands) were examined prospectively with ultrasonography and the results were compared with arthroscopy and MRI findings. We studied the visibility of the SL ligament and the SL distance on side-to-side comparison and performed a method comparison between MRI/arthroscopy and ultrasound, testing for distinction and accordance. Cut-off values for the SL distance indicating a lesion were determined and all parameters were used for developing a score.

RESULTS

An intact ligament appears as a hyperechogenic, fibrillary structure and shows discontinuity or a hypoechogenic space when injured. An intact ligament was visible dorsally in 89.6 % and palmarly in 83.3 %. The SL distance for an intact ligament was 5/2/5.1 mm for the dorsal/middle/palmar aspect (range 3.2-6.7/0.9-4/3.1-7.8 mm) and 6.4/3/6.3 mm (range 5-9.4/2-6.2/4-9.3 mm) for a lesion. The difference between the right and left hand with an intact ligament was a maximum of 2.1/1.1/1.8 mm, an average of 0.4/0.2/0.2 mm; in case of an injury, the maximum difference was 1.2/0.9/1.1 mm. Distance values for radial and ulnar deviation were physiological but partly unpredictable. The cut-off values determined for a lesion are 5.05 mm for the dorsal aspect (sensitivity/specificity 0.95/0.60), 1.95 mm for the middle (1/0.62) and 6.15 mm for the palmar aspect (0.55/0.85). The created sonographic SL ligament score has a high AUC (area under the curve) of 0.93, a sensitivity of 85 % and a specificity of 90 %.

CONCLUSION

The parameters, especially when combined to a score, allow to state whether the SL ligament is intact or not. Ultrasound can, therefore, be recommended as a diagnostic and screening method for an SL ligament lesion und should be used as a routine tool. The criteria must be checked from a perspective with high case numbers.

Для цитирования: Handschak Tino, Hofmann Gunther, Braunschweig Rainer, Tamouridis Georgios, Siemers Frank. [Establishing a standardized diagnostic Procedure for sonographic Imaging and Evaluation of the scapholunate Ligament].. Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V.... 2022. DOI: 10.1055/a-1718-3552.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.