MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/jss.2017.10.05

Медицинская библиотека · Journal of spine surgery (Hong Kong) · 2017

C7 intra-laminar screws for complex cervicothoracic spine surgery-a case series.

Wilson Peter John, Selby Michael Derrick

СтатьяПеревод в очереди

Аннотация

BACKGROUND

C7 has relatively unique anatomy compared to the remainder of the subaxial cervical spine (C3-C6) and upper thoracic spine. The C7 laminar has been previously reported in feasibility and biomechanical studies as an adequate fixation point in contrast to the lateral mass or pedicles, with few reports of its use in clinical practice. The purpose of this study was to review the safety and efficacy of using the C7 laminar as a fixation point in constructs involving the cervical spine and cervicothoracic junction.

METHODS

Between February 2013 and July 2016, 10 patients (6 males, 4 females) had 19 C7 intra-laminar screws sited (bilateral in 9 patients, unilateral in 1 patient). Six patients had trauma as an underlying etiology, 2 of which had pseudoarthrosis from prior surgery. Three patients had cervical myelopathy from degenerative disease, 2 of which required anterior and posterior instrumentation for correction of deformity and 1 which had stand-alone posterior fixation. One patient had stabilization for an underlying malignancy.

RESULTS

One patient died 2 weeks following their high cervical injury secondary to complications of respiratory failure. None of the remaining 9 patients were noted to have construct failure at a median follow up of 1 year (range, 6 months to 4 years) and all were noted to have satisfactory positioning of the instrumentation on post-operative imaging. The patient with malignancy died 6 months later from extra-spinal disease, there was one wound breakdown requiring debridement without infection in a revision case, and one patient required laminectomy for post-traumatic syrinx formation.

CONCLUSIONS

The C7 laminar provides an alternative fixation point for constructs involving the subaxial cervical spine and cervicothoracic junction, with excellent safety and efficacy in this small series. Larger series are required to more clarify the risk profile of this technique.

Для цитирования: Wilson Peter John, Selby Michael Derrick. C7 intra-laminar screws for complex cervicothoracic spine surgery-a case series.. Journal of spine surgery (Hong Kong). 2017. DOI: 10.21037/jss.2017.10.05.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.