A 5-year prospective clinical study of submerged and nonsubmerged Paragon system implants in the edentulous mandible.

Eliasson Alf, Narby Birger, Ekstrand Karl, Hirsch Jan, Johansson Anders, Wennerberg Ann

Сравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The aim of this investigation was to evaluate the clinical outcome of two different surgical protocols in the edentulous mandible: submerged and nonsubmerged. Further, the Paragon dental implant with a titanium plasma-sprayed surface was evaluated.

MATERIALS AND

METHODS

Twenty-nine consecutively treated patients with 168 implants supporting fixed prostheses were included. All but 3 patients were provided 6 implants, placed via nonsubmerged healing on one side and submerged healing on the other. Data were collected from patient records and radiographs. Twenty-four patients participated in the 5-year clinical follow-up examination.

RESULTS

After 5 years, all patients still had their mandibular fixed prostheses in function. Cumulative survival rates were 100% for prostheses and 99.4% for implants. However, 3 implants fractured in 1 patient. One submerged implant was lost before loading but no further implants were lost during follow-up. The radiographic bone loss was small for all implants with a mean of 0.14 mm (standard deviation [SD]: 0.37) at 1 year and 0.42 mm (SD: 0.48) at 5 years for nonsubmerged implants and 0.17 mm (SD: 0.32) at 1 year and 0.51 mm (SD: 0.33) at 5 years for submerged implants. Nineteen implants (including the 3 that fractured) presented annual bone loss exceeding 0.2 mm after the first year, yielding a cumulative success rate of 86.2% after 5 years.

CONCLUSION

Single-stage surgery was shown to have the same predictability as two-stage surgery in the anterior edentulous mandible. Paragon implants with a titanium plasma-sprayed surface showed a fracture rate of 2.2% and a success rate of 86.2% after 5 years.

Для цитирования: Eliasson Alf, Narby Birger, Ekstrand Karl, Hirsch Jan, Johansson Anders, Wennerberg Ann. A 5-year prospective clinical study of submerged and nonsubmerged Paragon system implants in the edentulous mandible.. The International journal of prosthodontics. 2010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.