MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/nau.25434

Медицинская библиотека · Neurourology and urodynamics · 2024

Comparison of perioperative adverse events following suburethral sling placement using synthetic mesh, autologous rectus fascia, and autologous fascia lata in a national surgical registry.

Hong Christopher X, Son Young, Patel Vaishnavi J, Lince Kimberly, Gupta Priyanka

СтатьяПеревод в очереди

Аннотация

AIMS: To assess and compare 30-day perioperative adverse events following suburethral sling surgery using synthetic mesh, autologous rectus fascia, and autologous fascia lata in women.

METHODS

This was a retrospective cohort study of patients who underwent fascial or synthetic sling placement for stress urinary incontinence between 2008 and 2021 using the American College of Surgeons' National Surgical Quality Improvement Program database. Current Procedural Terminology codes were used to identify patients undergoing each type of sling procedure. Multivariable regression analysis with stepwise regression was used to assess the odds of composite adverse events (e.g., urinary tract infection, surgical site infection, pulmonary embolism, and other reportable events) between cohorts.

RESULTS

Of the 41 533 female patients who underwent isolated suburethral sling placement without concurrent procedures, 41 292 (99.4%) received a synthetic mesh sling, and 241 (0.6%) received an autologous facial sling. In the fascial sling cohort, 160 (66.4%) underwent rectus fascia harvest and 81 (33.6%) underwent fascia lata harvest. Sling surgeries involving autologous fascia were associated with increased odds of adverse events compared to those involving synthetic mesh, even after adjusting for confounders (adjusted odds ratio [aOR]: 3.63, 95% confidence interval [CI]: 2.56-5.15). Compared to fascial slings from rectus fascia, slings from fascia lata were associated with increased odds of composite adverse events (aOR: 2.11, 95% CI: 1.03-4.04). However, with the exclusion of urinary tract infections, the adverse event rate was similar between slings using the two fascial harvest techniques (aOR: 1.93, 95% CI: 0.81-4.63).

CONCLUSIONS

In this retrospective database study, suburethral sling surgeries using autologous fascia were independently associated with a 3.6-fold increase in odds of 30-day perioperative adverse events compared to sling surgeries using synthetic mesh.

Для цитирования: Hong Christopher X, Son Young, Patel Vaishnavi J, Lince Kimberly, Gupta Priyanka. Comparison of perioperative adverse events following suburethral sling placement using synthetic mesh, autologous rectus fascia, and autologous fascia lata in a national surgical registry.. Neurourology and urodynamics. 2024. DOI: 10.1002/nau.25434.