Journal of analytical toxicology · 2026
GC-FID quantification of methanol, ethanol, 2-propanol, acetone, ethylene glycol, diethylene glycol, 1,2-propylene glycol and 1,3-propylene glycol in plasma.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
El Amrani Mohsin, Zandbergen Arjan, Groot Mike, Bognar Tim, Smeijsters Erin H, van der Elst Kim C M
Аннотация
Alcohol and glycol ingestion, including substances such as methanol, ethylene glycol, and isopropanol, constitute a serious medical emergency that requires prompt diagnosis and treatment of patients. Rapid and accurate quantification of these compounds in plasma is essential to guide clinical decision-making and prevent delays in treatment that could result in irreversible organ damage or death. Many healthcare facilities lack analytical methods capable of simultaneously quantifying both alcohols and glycols in a single run. This study describes the development and validation of a rapid gas chromatography-flame ionization detection (GC-FID) method for the simultaneous screening and quantification of methanol, ethanol, 2-propanol, acetone, ethylene glycol, diethylene glycol, 1,2-propylene glycol, and 1,3-propylene glycol in human plasma. Plasma samples were prepared using a protein precipitation technique with acetonitrile containing two internal standards: 2-butanol and 1,4-butanediol. Acetonitrile effectively precipitated plasma proteins. The supernatant was then subjected to GC-FID analysis for quantification of the target al.ohols and glycols. The total analytical run time was 5 minutes, enabling the quantification of eight analytes in a single injection. The method demonstrated excellent linearity, with correlation coefficients (R2) exceeding 0.9995 for all compounds. The linear dynamic range was 40-1280 mg/L for methanol, 2-propanol, acetone, ethylene glycol, diethylene glycol, 1,2-propylene glycol, and 1,3-propylene glycol, and 80-2560 mg/L for ethanol. Within-run and between-run precision and accuracy (CV and bias) for all analytes were within the predefined acceptance criteria of ±15%. No significant interference, carry-over, or matrix effects were observed, confirming the method's selectivity and robustness. The developed GC-FID method enables rapid, accurate, and simultaneous quantification of toxic alcohols and glycols in plasma within a 5-minute run time. The excellent linearity, precision, and selectivity of the method met al. analytical performance criteria, making it well-suited for routine clinical use. This method provides a valuable tool for timely diagnosis and management of suspected toxic alcohol and glycol ingestions in patients in emergency settings.