MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ajts.ajts_21_19

Медицинская библиотека · Asian journal of transfusion science · 2022

Outcome of type and screen versus crossmatch in cardiovascular surgery patients: A comparative study.

Pokhrel Anupa, Jain Ashish, Marwaha Neelam, Singh Rana Sandip

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The need for an anti-human globulin (AHG) cross-match (XM) when the antibody screen (ABS) is negative is debatable and a matter of policy.

AIM: (1) To compare the outcomes of type and screen (T and S) method versus the AHG-XM in terms of posttransfusion alloimmunization and hemolytic reactions. (2) Calculation of XM transfusion ratio in both groups.

MATERIALS AND

METHODS

The study included 200 patients undergoing elective cardiovascular surgery. Group I patients (n = 100) were issued packed red blood cell units after ABO and RhD typing, an ABS followed by an immediate spin XM (T and S protocol), while Group II (n = 100) patients by an AHG-XM. In Group II patients, if incompatibility was found, then an ABS and identification were performed. A posttransfusion ABS and a direct antiglobulin test (DAT) was done on the 4th day. The XM, ABS (3-cell panel) and DAT were done using the gel technique (Bio-Rad, Switzerland). Thus, the outcomes of T and S method versus the AHG-XM in terms of posttransfusion alloimmunization and hemolytic reactions was measured. The XM transfusion ratio was also calculated in both groups.

RESULTS

In each of Groups I and II, 99 patients (99%) were transfused. There was no significant difference between the two groups based on previous transfusion (P = 0.621) or combined history of transfusion and pregnancy (P = 1). In Group I, all the patients were negative for ABS. In Group II, an AHG-XM was incompatible for 1 patient (1%) due to anti-c and anti-E alloantibodies and had a history of pregnancy as well as transfusion. In both the groups, none of the patients had any adverse transfusion reaction and the posttransfusion ABS and DAT were negative.

CONCLUSION

ABS is a better tool than AHG-XM in detecting alloantibodies in patients having the previous history of transfusion and/or pregnancy.

Для цитирования: Pokhrel Anupa, Jain Ashish, Marwaha Neelam, Singh Rana Sandip. Outcome of type and screen versus crossmatch in cardiovascular surgery patients: A comparative study.. Asian journal of transfusion science. 2022. DOI: 10.4103/ajts.ajts_21_19.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.