MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41390-024-03476-x

Медицинская библиотека · Pediatric research · 2024

Formula with large, milk phospholipid-coated lipid droplets in late-moderate preterm infants: a double-blind RCT.

Kakaroukas Andreas, Abrahamse-Berkeveld Marieke, Hayes Louise, McNally Richard J Q, Berrington Janet E, van Elburg Ruurd M, Embleton Nicholas D

СтатьяРандомизированное исследованиеEquivalence TrialПеревод в очереди

Аннотация

BACKGROUND

Limited evidence exists on the preferred feeding method when breastfeeding is not possible in late and moderate preterm (LMPT) infants. This RCT evaluates growth, safety, and tolerance of a concept infant formula (IF) with large, milk phospholipid-coated lipid droplets enriched in dairy lipids in LMPT infants with primary objective to demonstrate non-inferiority of daily weight gain from randomization to 3 months corrected age compared to a standard IF.

METHODS

LMPT infants were randomized before or around term equivalent age to either the concept (n = 21) or standard IF (n = 20). Forty-one breastfed (BF) infants served as reference.

RESULTS

Due to unintended low recruitment, non-inferiority in daily weight gain could not be demonstrated for the Concept compared to the Control group, but was compared to the BF group. Other outcomes were similar between the formula groups, except for an apparent larger head circumference gain in the Concept group. No apparent differences in growth and body composition outcomes were observed between the Concept and BF reference groups.

CONCLUSION

This small-scale study suggests the concept IF is a safe alternative for parents who choose IF to feed their LMPT infant. Larger trials are needed to better determine impacts on head growth or body composition.

IMPACT: In a small group of late and moderate preterm infants, growth from randomization until 3 months corrected age of infants fed with a concept infant formula with large, milk phospholipid-coated lipid droplets was not -significantly different from infants fed a standard infant formula. Infants in the Concept group had non-significant larger gain in head circumference compared to the Control group; larger trials are needed to confirm this finding. Both formulas were well-tolerated, with no differences in adverse events. The concept formula is potentially a safe alternative for parents of moderate to late preterm infants who choose to use formula milk.

Для цитирования: Kakaroukas Andreas, Abrahamse-Berkeveld Marieke, Hayes Louise, McNally Richard J Q, Berrington Janet E, van Elburg Ruurd M, Embleton Nicholas D. Formula with large, milk phospholipid-coated lipid droplets in late-moderate preterm infants: a double-blind RCT.. Pediatric research. 2024. DOI: 10.1038/s41390-024-03476-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.