m+Medelevator.RU
← Поиск публикаций
Pediatric dermatology · 2003

Tissue-engineered skin in the healing of wound stumps from limb amputations secondary to purpura fulminans.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Yongni, Liu Yifan, Pan Zhicheng, Gao Hui, Martin RobRoy L, Huang Xinwei

Аннотация

BACKGROUND: The single-leg squat test (SLST) is supported by evidence for reliability and validity across various visual rating methods, but the optimal number of ordinal categories for assessing movement quality remains unclear. The study aims to determine the most informative and reliable number of ordinal scoring categories for visually rating the SLST.

METHODS: A total of 58 subjects with lower extremity injuries participated. A single therapist rated the SLST with a 1-week interval to establish intra-rater reliability. Two therapists independently rated the SLST at the same time point to establish inter-rater reliability. Two-, three-, and four-category ordinal scales were simultaneously used to evaluate SLST performance in rating the components of trunk deviation, hip adduction, and lower extremity internal rotation. Reliability was assessed using unweighted kappa (κ) values.

RESULTS: The overall intra-rater reliability was κ = 0.60, 0.35, and 0.20, with inter-rater reliability being κ = 0.60, 0.61, and 0.33 for the two-, three-, and four-category scales, respectively. When specifically looking at the components of trunk deviation, hip adduction, and lower extremity internal rotation, intra-rater reliability was moderate to good for two-category scales (κ = 0.47-0.65), fair to good for three-category scales (κ = 0.3-0.7), and fair to good for four-category scales (κ = 0.36-0.65). Inter-rater reliability for the three components was good to excellent (κ = 0.65-0.86) for the two-category, good to excellent (κ = 0.69-0.86) for the three-category, and fair to excellent (κ = 0.55-0.76) for the four-category.

CONCLUSION: When applied to specific movement components, the three-category ordinal scale demonstrated the best balance between detailed assessment and reliability for visually rating trunk deviation, hip adduction, and lower extremity internal rotation during the SLST in patients with lower extremity injuries.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты