MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.aog.0000114985.22844.6d

Медицинская библиотека · Obstetrics and gynecology · 2004

Immediate maternal and neonatal effects of forceps and vacuum-assisted deliveries.

Johnson Jennifer H, Figueroa Reinaldo, Garry David, Elimian Andrew, Maulik Dev

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To estimate the differences in immediate maternal and neonatal effects of forceps and vacuum-assisted deliveries.

METHODS

We conducted a medical record review of all forceps and vacuum-assisted deliveries that occurred from January 1, 1998, to August 30, 1999, at Winthrop-University Hospital. Maternal demographics and delivery characteristics were recorded. Maternal outcomes, such as use of episiotomy and presence of lacerations, were studied. Neonatal outcomes evaluated were Apgar scores, neonatal intensive care unit admissions, cephalohematomas, instrument marks and bruising, and caput and molding.

RESULTS

Of 508 operative vaginal deliveries, 200 were forceps and 308 were vacuum assisted. Forceps were used more often than vacuum for prolonged second stage of labor (P =.001). There was a higher rate of epidural (P =.02) and pudendal (P <.001) anesthesia, episiotomies (P =.01), maternal third- and fourth-degree perineal (P <.001) and vaginal lacerations (P =.004) with the use of forceps, whereas periurethral lacerations were more common in vacuum-assisted (P =.026) deliveries. More instrument marks and bruising (P <.001) were found in the neonates delivered by forceps, whereas there was a greater incidence of cephalohematomas (P =.03) and caput and molding (P <.001) in the neonates delivered with vacuum. Multivariable logistic regression analysis showed that forceps use was associated with an increase in major perineal and vaginal tears (odds ratio [OR] 1.85; 95% confidence interval [CI] 1.27, 2.69; P =.001), an increase in instrument marks and bruising (OR 4.63; 95% CI 2.90, 7.41; P <.001) and a decrease in cephalohematomas (OR 0.49; 95% CI 0.29, 0.83; P =.007) compared with the vacuum.

CONCLUSIONS

Maternal injuries are more common with the use of forceps. Neonates delivered with forceps have more facial injuries, whereas neonates delivered with vacuum have more cephalohematomas.

LEVEL OF EVIDENCE: II-3

Для цитирования: Johnson Jennifer H, Figueroa Reinaldo, Garry David, Elimian Andrew, Maulik Dev. Immediate maternal and neonatal effects of forceps and vacuum-assisted deliveries.. Obstetrics and gynecology. 2004. DOI: 10.1097/01.aog.0000114985.22844.6d.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.