m+Medelevator.RU
← Поиск публикаций
Journal of the mechanical behavior of biomedical materials · 2025

Effect of stent-graft length and compliance on aortic hemodynamics in a bench-top physiological flow circuit.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shahbad Ramin, Zermeno Elizabeth, Razian Sayed Ahmadreza, Maleckis Kaspars, Jadidi Majid, Desyatova Anastasia

Аннотация

The aortic elasticity plays a vital role in buffering pulsatile blood flow, propelling blood to distal organs and the heart, and reducing cardiac workload. Aortic repair with a stent-graft can reduce this elasticity and hinder the aorta's ability to effectively perform its function. Conventional stent-grafts are associated with increased arterial stiffness, elevated pulse wave velocity (PWV), and adverse hemodynamic changes. This is largely driven by stiffness mismatch between the stent-graft and the native aortic wall, which alters mechanical compliance and hemodynamic response. This study evaluates a novel compliant nanofiber stent-graft (NF-SG) developed to closely mimic native aortic mechanics. Using a bench-top physiological flow circuit, we assessed the hemodynamic impacts of stent-graft stiffness and length on arterial parameters, including PWV, pulse pressure (PP), and distensibility in vitro, and compared these effects with conventional stent-grafts. Stent-graft stiffness significantly affected PWV, PP, and distensibility. Conventional stent-grafts showed 14 %-52 % increase in PWV depending on stent-graft length (p < 0.001), 5 %-32 % increase in PP, and 82 % reduction in mid-graft distensibility. In contrast, NF-SGs maintained PWV and PP near baseline levels with marginal effect of the stent-graft length. Distensibility in the mid-graft was reduced by 13 %-20 %, depending on the stent-graft length. The NF-SG's superior compliance and reduced hemodynamic perturbation were attributed to its mechanically optimized fabric and skeleton design. These findings underscore the clinical potential of the compliant stent-grafts to significantly mitigate long-term cardiovascular complications and preserve aortic functionality post-intervention.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты