m+Medelevator.RU
← Поиск публикаций
JACC. Asia · 2026

New-Generation Transcatheter Valves for Extremely Small Aortic Annuli.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Shirai Shinichi, Hioki Hirofumi, Yamamoto Masanori, Ishizu Kenichi, Hayashi Masaomi, Ando Kenji, Tokuda Takahiro, Watanabe Yusuke, Naganuma Toru, Yamanaka Futoshi, Noguchi Masahiko, Ohno Yohei, Shimura Tetsuro, Yashima Fumiaki, Nakazawa Gaku, Asami Masahiko, Izumo Masaki, Nishina Hidetaka, Ueno Hiroshi, Suzuyama Hiroto, Yamasaki Kazumasa, Nishioka Kenji, Hachinohe Daisuke, Fuku Yasushi, Otsuka Toshiaki, Hayashida Kentaro, OCEAN-TAVI Investigators

Аннотация

BACKGROUND: Patients with extremely small aortic annuli are at increased risk of residual gradients and prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR). Comparative data on contemporary valve platforms in this subset remain limited.

OBJECTIVES: The authors aimed to compare early clinical and hemodynamic outcomes among balloon-expandable valves (BEVs), supra-annular self-expanding valves (SA-SEVs), and intra-annular self-expanding valves (IA-SEVs) in patients with severe aortic stenosis and extremely small annuli.

METHODS: Patients with annular area <314 mm2 from the OCEAN-TAVI registry were analyzed using multinomial propensity score overlap weighting. Primary outcomes were severe PPM, mean transvalvular pressure gradient ≥20 mm Hg, and paravalvular leakage (PVL) ≥mild.

RESULTS: Among 385 patients, 125, 136, and 124 underwent BEV, SA-SEV, and IA-SEV implantation, respectively. Effective sample sizes after overlap weighting were 92.4, 93.6, and 85.4, with a median follow-up of 358 days. Adjusted probabilities of severe PPM were similarly low (1.6%, 2.0%, and 2.7%; P = 0.85). mean transvalvular pressure gradient ≥20 mm Hg occurred in 4.5%, 8.3%, and 2.3%, respectively (P = 0.19). PVL ≥mild was numerically more frequent with SEV than BEV (15.8%, 27.3%, and 27.0%; P = 0.09), with adjusted odds ratios versus BEV of 1.92 (95% CI: 0.96-3.84) for SA-SEV and 1.83 (95% CI: 0.91-3.70) for IA-SEV. Major complications and 1-year mortality were similar among groups.

CONCLUSIONS: Contemporary TAVR platforms showed broadly similar early outcomes, although PVL ≥mild was numerically more frequent with self-expanding valves.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты