m+Medelevator.RU
← Поиск публикаций
European heart journal. Acute cardiovascular care · 2024

Novel troponin fragmentation assay to discriminate between Takotsubo syndrome and acute myocardial infarction.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Airaksinen Juhani K E, Tuominen Tuulia, Paana Tuomas, Hellman Tapio, Vasankari Tuija, Salonen Selma, Junes Helea, Linko-Parvinen Anna, Pallari Hanna-Mari, Strandberg Marjatta, Teppo Konsta, Jaakkola Samuli, Wittfooth Saara

Аннотация

AIMS: Cardiac troponin levels are elevated in Takotsubo syndrome (TTS) with significant overlap to acute myocardial infarction (MI). Long and intact cardiac troponin T (cTnT) forms are typical for MI. This study sought to assess whether the fragmentation composition of cTnT release in TTS differs from MI.

METHODS AND RESULTS: The concentration of long molecular forms of cTnT (long cTnT) was measured with a novel upconversion luminescence immunoassay and total cTnT with a commercial high-sensitivity cTnT assay in 24 TTS patients and in 84 Type 1 MI patients. The ratio of long to total cTnT (troponin ratio) was determined as a measure of cTnT fragmentation. Troponin ratio was lower in TTS patients [0.13 (0.10-0.20) vs. 0.62 (0.29-0.96), P < 0.001]. In the receiver operating characteristic curve analyses, troponin ratio showed a better predictive power than total cTnT in discriminating TTS and MI patients {area under the curve [AUC] 0.869 [95% confidence interval (CI) 0.789-0.948] vs. 0.766 [95% CI 0.677-0.855], P = 0.047}. When restricting the analysis to patients with total cTnT below 1200 ng/L (maximal value in TTS patients), the respective AUC values for total cTnT and troponin ratio were 0.599 (95% CI 0.465-0.732) and 0.816 (95% CI 0.712-0.921) (P = 0.003). At a cut-off point of 0.12, troponin ratio correctly identified 95% of MI patients and 50% of TTS patients.

CONCLUSION: In contrast to Type 1 MI, only a small fraction of circulating cTnT in TTS exists in intact or long molecular forms. This clear difference in troponin composition could be of diagnostic value when evaluating patients with cTnT elevations and suspicion of TTS.

CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04465591.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты