m+Medelevator.RU
← Поиск публикаций
Biosensors · 2026

New Concept of Intraoperative Fluorescence Diagnostics for Photodynamic Dosimetry of Tumors Using Chlorin-Based Photosensitizers.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Efendiev Kanamat, Moskalev Arkadii, Alekseeva Polina, Borodkin Alexander, Skobeltsin Alexey, Makarov Vladimir, Kalyagina Nina, Linkov Kirill, Gilyadova Aida, Shpileva Olga, Ilyasova Dinara, Pisareva Tatiana, Kozlova Polina, Rakhmanova Aidai, Shiryaev Artem, Loschenov Victor

Аннотация

Photodynamic therapy (PDT) with chlorin-based photosensitizers requires real-time monitoring of photosensitizer distribution and photobleaching to guide treatment, yet existing endoscopic fluorescence systems rely on short-wavelength (375-450 nm) excitation that is spectrally incompatible with 660 nm chlorin e6 (Ce6)-PDT, forcing interruption of therapy for diagnostic imaging. We developed VENERA-red-660, a dual-channel endoscopic system using a single 660 nm laser for simultaneous white-light and Ce6 fluorescence imaging (>670 nm detection) without interrupting irradiation. System sensitivity was validated on optical phantoms (Ce6 0.1-5.0 mg/L), and phototheranostics was performed in patients with basal cell carcinoma (n = 5), vulvar intraepithelial neoplasia grade III (n = 3), and peritoneal carcinomatosis (n = 10) using intravenous chlorin-based photosensitizer. Phantom testing showed a linear fluorescence response (R2 = 0.998) down to the lowest tested concentration of 0.1 mg/L. Pre-PDT fluorescence contrast indices confirmed photosensitizer selectivity in all three tumor types, decreasing by 57%, 66%, and 60% after treatment, consistent with photobleaching; continuous intra-PDT monitoring confirmed progressive photobleaching kinetics, and confocal microscopy verified cellular-level Ce6 selectivity. Increased backscattered laser signal after PDT was consistent with treatment-induced changes in tissue optical properties. These pilot findings demonstrate that single-source phototheranostic monitoring is feasible across external and laparoscopic access routes, supporting further evaluation of VENERA-red-660 as a tool for intraoperative PDT dosimetry.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты