MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/rg.322115068

Медицинская библиотека · Radiographics : a review publication of the Radiological Society of North America, Inc · 2012

Migration of intrauterine devices: radiologic findings and implications for patient care.

Boortz Hillary E, Margolis Daniel J A, Ragavendra Nagesh, Patel Maitraya K, Kadell Barbara M

СтатьяПоддержка исследования: вне правительства СШАОбзорПеревод в очереди

Аннотация

Intrauterine devices (IUDs) are a commonly used form of contraception worldwide. However, migration of the IUD from its normal position in the uterine fundus is a frequently encountered complication, varying from uterine expulsion to displacement into the endometrial canal to uterine perforation. Different sites of IUD translocation vary in terms of their clinical significance and subsequent management, and the urgency of communicating IUD migration to the clinician is likewise variable. Expulsion or intrauterine displacement of the IUD leads to decreased contraceptive efficacy and should be clearly communicated, since it warrants IUD replacement to prevent unplanned pregnancy. Embedment of the IUD into the myometrium can usually be managed in the outpatient clinical setting but occasionally requires hysteroscopic removal. Complete uterine perforation, in which the IUD is partially or completely within the peritoneal cavity, requires surgical management, and timely and direct communication with the clinician is essential in such cases. Careful evaluation for intraabdominal complications is also important, since they may warrant urgent or emergent surgical intervention. The radiologist plays an important role in the diagnosis of IUD migration and should be familiar with its appearance at multiple imaging modalities.

Для цитирования: Boortz Hillary E, Margolis Daniel J A, Ragavendra Nagesh, Patel Maitraya K, Kadell Barbara M. Migration of intrauterine devices: radiologic findings and implications for patient care.. Radiographics : a review publication of the Radiological Society of North America, Inc. 2012. DOI: 10.1148/rg.322115068.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.