INTRODUCTION

Coronavirus disease 2019 (COVID-19) is a highly contagious disease transmitted by contact, droplets, and aerosols. Front line health-care workers (HCWs), particularly emergency physicians and acute care providers, are vulnerable to being exposed while treating their sick patients. Despite appropriate personal protective equipment use, HCW gets infected, suggesting the need for multiple layers of protection such as barrier devices.

METHODS

We aimed to determine the effectiveness of our novel "Resuscitation Cover All"(RCA) in reducing the exposure of HCW to simulated respiratory particles and its feasibility during cardio pulmonary resuscitation (CPR). This was a pilot simulation-based study. Five CPR simulation sessions were performed in Standard and RCA protocols, individually. Exposures through contact, droplets, and aerosols were simulated using a standardized volume of liquid detergent. Under Wood's lamp illumination, exposures of participants were compared between the protocols. Rate and depth of chest compressions, time taken to intubate, interruptions in CPR, and first-pass success were analyzed.

RESULTS

Overall mean exposure in standard protocol was 4950.4 ± 1461.6 (95%confidence interval [CI]:3135.7-6765.2) sq.pixels and RCA protocol was 2203.6 ± 1499.0 (95%CI: 342.4-4064.9) sq.pixels (P = 0.019). In standard, chest compressor had the highest exposure of 3066.6 ± 1419.2 (95%CI: 2051.3-4081.9) sq.pixels followed by defibrillator assistant 1166.4 ± 767.4 (95%CI: 617.4-1715.4) sq.pixels. Chest compressor of RCA had reduced exposure compared to that of standard (P < 0.001). Hands were the most frequently exposed body part. Airway manager of RCA had no exposure over head and neck in any session. No significant difference in CPR performance metrics was observed.

CONCLUSION

This pilot simulation-based study shows that the novel RCA device could minimize the exposure of HCW to simulated respiratory particles during CPR. Also, it might not alter the high-quality CPR performance metrics. We need more real-life evidence.

Для цитирования: Raju K N J Prakash, Ayyan S Manu, Anandhi D, Jain Naman, Ganessane Ezhilkugan. Effectiveness of "Resuscitation Cover All" in Minimizing COVID-19 Transmission to Health-Care Workers during Cardiopulmonary Resuscitation.. Journal of global infectious diseases. 2022. DOI: 10.4103/jgid.jgid_182_21.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.